A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetic Resonance Imaging-Based Monitoring of the Accumulation of Polyethylene Terephthalate Nanoplastics. | LitMetric

Polyethylene terephthalate (PET) is one of the most produced plastic materials in the world. The emergence of microplastics and nanoplastics (MPs/NPs) as a significant environmental contaminant has become a matter of increasing concern. While the toxicological effects of PET NPs have been widely researched, there is a lack of methodologies for studying their accumulation. The present study introduces a novel method to monitor the distribution of PET NPs in germinating wheat ( L.) seeds. This involves the functionalization of superparamagnetic iron oxide nanoparticles (SPIONs) with PET NPs (PET-fSPIONs) coupled with magnetic resonance microimaging (µMRI) to provide insight into their distribution within the seed. The present study has demonstrated that PET-fSPIONs accumulate in specific regions of germinating wheat seeds, including the shoot apical meristem, the radicle, the coleoptile, the plumule, and the scutellum. Furthermore, the accumulation of PET-fSPIONs has been shown to exert a discernible effect on spin-spin relaxation (), as observed via MRI and quantitative relaxation time analysis. The accumulation of PET NPs in embryo regions was also confirmed by SEM. Diffusion-weighted magnetic resonance imaging (DW-MRI) and non-invasive chemical shift imaging analyses demonstrated that PET NPs resulted in restricted diffusion within the highlighted areas, as well as an impact on lipid content. Our study reveals that using µMRI with fSPIONs provides a non-invasive method to monitor the biodistribution of PET nanoparticles in wheat seeds. Additionally, it offers valuable insights into the microstructural interactions of PET.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11434537PMC
http://dx.doi.org/10.3390/molecules29184380DOI Listing

Publication Analysis

Top Keywords

pet nps
20
magnetic resonance
12
wheat seeds
12
polyethylene terephthalate
8
pet
8
method monitor
8
germinating wheat
8
nps
5
resonance imaging-based
4
imaging-based monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!