: Perforator mapping is a mandatory tool for the preoperative planning of a microsurgical free flap, especially in breast reconstruction. Numerous methods for mapping have been described. In this study, we investigate the combined use of Dynamic Infrared Thermography (DIRT) and Colour Doppler Ultrasonography (CDUS) only to see whether it can eliminate the need for Computed Tomography Angiography (CTA). : A prospective study was conducted on 33 patients with deep inferior epigastric perforator (DIEP) flaps for breast reconstruction. DIRT, followed by CDUS and CTA, was performed preoperatively and perforators were confirmed intraoperatively. : From 135 hot spots found on DIRT, 123 perforators were confirmed by CDUS (91.11%). A total of 86.66% of the perforator vessels detected on CTA have their correspondent on DIRT, while 95.12% have their correspondent on CDUS. No statistically significant difference ( > 0.05) was found comparing DIRT vs. CTA and CDU vs. CTA. The average DIRT time was 121.54 s and CDUS 232.09 s. The mean sensitivity for DIRT was 95.72% and 93.16% for CDUS. : DIRT combined with CDUS can precisely and efficiently identify suitable perforators without the need for CTA in DIEP breast reconstruction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11433019 | PMC |
http://dx.doi.org/10.3390/jpm14090969 | DOI Listing |
Ann Surg Oncol
January 2025
Division of Breast Surgery, Department of Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan.
Cureus
December 2024
Surgery, Kokura Memorial Hospital, Kitakyushu, JPN.
Silicone breast implants (SBIs) are commonly used for breast reconstruction and cosmetic surgery. However, long-term complications associated with SBI, such as rupture and infection, require careful monitoring. Here, we report a case in which coronavirus disease 2019 infection led to immunosuppression and secondary bacterial infection, resulting in skin ulceration and eventual removal of the SBI.
View Article and Find Full Text PDFAdv Radiat Oncol
February 2025
Department of Advanced Radiation Oncology and Proton Therapy, Inova Schar Cancer Institute, Fairfax, Virginia.
Purpose: This study evaluates the hypothesis that a volumetric skin-sparing planning technique (SSPT) will reduce acute dermatitis in patients treated to the breast or chest wall (CW) with proton pencil-beam scanning (PBS).
Methods And Materials: In January 2022, our center incorporated volumetric-based skin-sparing objectives in addition to skin hot spot evaluation as an SSPT. The SSPT incorporated an objective to limit the volume of a skin evaluation structure (skin-eval) receiving 95% of the prescription dose or more (V95%Rx) to ideally < 50%.
Plast Reconstr Surg Glob Open
January 2025
From the Department of Plastic, Reconstructive, and Aesthetic Surgery, Geneva University Hospitals, Geneva University, Geneva, Switzerland.
Background: Prepectoral (PP) immediate implant-based breast reconstruction (IBBR) is gaining popularity over the retropectoral (RP) breast reconstruction technique. This study aims to compare complication rates across different body mass index (BMI) groups in patients undergoing PP or RP IBBR.
Methods: A monocentric retrospective analysis was conducted on patients who underwent mastectomy and IBBR from January 2018 to December 2023.
Plast Reconstr Surg Glob Open
January 2025
From the Division of Plastic and Reconstructive Surgery, Washington University School of Medicine in Saint Louis, St. Louis, MO.
We present an approach for evaluating abdominal computed tomography (CT) scans that generates reproducible measures relevant to donor site morbidity after abdominally based breast reconstruction. Seventeen preoperative CT metrics were measured in 20 patients with software: interanterior superior iliac spine distance; abdominal wall protrusion; interrectus distance; rectus abdominis width, thickness, and width-to-thickness ratio; abdominal wall thickness; subcutaneous fat volume; visceral fat volume; right/left psoas volumes and densities; and right/left rectus abdominis volumes and densities. Two operators performed measures to determine interrater reliability (n = 10).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!