A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The role of sampling in the detection of microbial contamination on cadaveric allograft skin used as a biological wound dressing. | LitMetric

The availability of cryopreservation and low temperature storage techniques for cadaveric allograft skin allows it to be preserved while microbial assessments are made before its use as a temporary biological dressing on burn wounds. In a 300-donor, 5-year prospective study, we tested ten skin samples from defined areas on each donor for microbiological contamination. Although the skin from 52.3 per cent of the donors possessed some detectable residual microbial contamination after surgical body preparation and skin removal, such contamination was limited to an average of 1.4 areas per body, leaving 86 per cent of all skin obtained free from detectable contamination and suitable for use as biological wound dressings. The number of skin samples tested per donor body determined the accuracy of detection of the presence of contamination. Testing one skin sample per donor body yielded a correct skin assessment 92 per cent of the time, while testing five skin samples increased the accuracy to 96 per cent, and testing ten skin samples yielded a 99.9 per cent accuracy in detection of skin contamination. Thus, it is within the ability of a skin bank to set the limits of microbiological risk to patients receiving processed cadaveric allograft skin.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0305-4179(85)90181-0DOI Listing

Publication Analysis

Top Keywords

skin samples
16
skin
14
cadaveric allograft
12
allograft skin
12
microbial contamination
8
biological wound
8
ten skin
8
donor body
8
accuracy detection
8
testing skin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!