A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Concordance between LDL-C estimated by various formulas and directly measured LDL-C. | LitMetric

Background: Although direct measurement of LDL cholesterol (LDL-C) in blood is possible, there are several formulas for its estimation. The performance and concordance of these formulas have not been evaluated in Colombia.

Objective: To determine the concordance between LDL-C directly measured using the enzymatic technique and existing methods to calculate it.

Methods: Study of diagnostic tests, and concordance. We analyzed complete lipid profile samples, which included direct measurement of LDL-C, from 2014 to 2022 at Hospital Universitario San Ignacio (Bogotá, Colombia). The direct LDL-C measurements were compared with estimations using the DeLong, Sampson, Friedewald, extended Martin/Hopkins, Anandaraja, and Cordova methods. Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were employed, conducting subgroup analyses based on triglycerides (TG), and LDL-C levels. Kappa coefficients assessed agreement in LDL-C risk categories according to dyslipidemia guidelines.

Results: A total of 2144 samples were evaluated. The formulas with the best CCC were DeLong (0.971) and Sampson (0.969), with no relevant differences. The extended Martin/Hopkins formula (0.964) and the Friedewald formula (0.964) also performed well. The Anandaraja (0.921) and Cordova (0.881) equations exhibited inferior performance. For all formulas, a decrease in concordance was observed when triglycerides were ≥400 mg/dL or when LDL-C was <100 mg/dL. Most formulas demonstrated optimal agreement when assessed using risk categories according to dyslipidemia guidelines, except for Anandaraja and Cordova.

Conclusions: The DeLong, Sampson, extended Martin/Hopkins, and Friedewald formulas show the best concordance with directly measured LDL-C, so in most cases the results can be considered interchangeable. However, the Anandaraja and Cordova formulas are not recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacl.2024.08.009DOI Listing

Publication Analysis

Top Keywords

concordance ldl-c
8
directly measured
8
ldl-c
8
direct measurement
8
extended martin/hopkins
8
formula 0964
8
concordance
6
formulas
5
ldl-c estimated
4
estimated formulas
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!