A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The impact of blood type and body size on successful bridging to heart transplantation using intra-aortic balloon pump or surgically implanted microaxial left ventricular assist device. | LitMetric

Objective: Waitlist time for United Network for Organ Sharing Status 2 heart transplant candidates has steadily increased. We compared a bridging strategy using either the Impella 5.0/5.5 ("Impella") or intra-aortic balloon pump with a durable left ventricular assist device in patients with blood type O stratified by body habitus.

Methods: The United Network for Organ Sharing registry was queried for adults listed for de novo heart transplantation (without dialysis) supported by the Impella, an intra-aortic balloon pump, or the HeartMate 3 left ventricular assist device. The primary outcome was 1-year postlisting survival, defined as the sum of waitlist time and post-heart transplant survival time if the candidate underwent heart transplantation.

Results: In total, 2942 candidates were included (Impella: 214; intra-aortic balloon pump: 1326; HeartMate 3: 1402). Listing with the Impella or intra-aortic balloon pump was associated with worse postlisting survival compared with the HeartMate 3 left ventricular assist device in type O candidates (Impella: hazard ratio, 2.90 [95% CI, 1.48-5.67], P = .002; intra-aortic balloon pump: hazard ratio, 2.42 [95% CI, 1.59-3.68], P < .001) but less so in non-type O candidates. Further analysis of type O candidates demonstrated that the Impella and intra-aortic balloon pump were associated with a lower risk of postlisting mortality among those with normal height (25-75th percentile) and nonobese (body mass index <30) (Impella: hazard ratio, 1.78 [95% CI, 0.61-5.18], P = .292; intra-aortic balloon pump: hazard ratio, 1.28 [95% CI, 0.67-2.45], P = .455); among those not of normal height and nonobese, the Impella and intra-aortic balloon pump were associated with an elevated risk of postlisting mortality (Impella: hazard ratio, 3.65 [95% CI, 1.68-7.95], P = .001; intra-aortic balloon pump: hazard ratio, 3.01 [95% CI, 1.95-4.67], P < .001).

Conclusions: Blood type O candidates listed with the Impella or intra-aortic balloon pump are at increased risk of postlisting mortality compared with a durable left ventricular assist device in the current organ allocation era. These effects are diminished among those with normal height and body habitus.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2024.09.028DOI Listing

Publication Analysis

Top Keywords

intra-aortic balloon
24
balloon pump
24
left ventricular
16
ventricular assist
16
assist device
16
blood type
8
heart transplantation
8
waitlist time
8
united network
8
network organ
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!