In the original publication [...].
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11430088 | PMC |
http://dx.doi.org/10.3390/cells13181575 | DOI Listing |
Indian J Nucl Med
November 2024
Center for Research and Production of Radioisotopes, Dalat Nuclear Research Institute, Vietnam Atomic Energy Institute (VINATOM), Da Lat City, Lam Dong Province, Vietnam.
Aims: This study aimed to evaluate the principal technical characteristics of a well-type gas-filled ionization chamber dose calibrator used in measuring radiopharmaceutical activity, namely accuracy, repeatability, and linearity. Furthermore, this work also explored the correlation between the device's response and the position and volume of the radiopharmaceutical I-131.
Materials And Methods: Experimental measurements were conducted on the ATOMLAB 500 dose calibrator using NIST traceable Cs-137 source to determine the accuracy and repeatability.
Sci Rep
January 2025
Department of Brain Sciences, Graduate School, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea.
Comput Med Imaging Graph
January 2025
The Department of Computer and Data Science, Case Western Reserve University, Cleveland, OH, USA; The Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
A generic and versatile CT Image Reconstruction (CTIR) scheme can efficiently mitigate imaging noise resulting from inherent physical limitations, substantially bolstering the dependability of CT imaging diagnostics across a wider spectrum of patient cases. Current CTIR techniques often concentrate on distinct areas such as Low-Dose CT denoising (LDCTD), Sparse-View CT reconstruction (SVCTR), and Metal Artifact Reduction (MAR). Nevertheless, due to the intricate nature of multi-scenario CTIR, these techniques frequently narrow their focus to specific tasks, resulting in limited generalization capabilities for diverse scenarios.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Anti-Aging Research Center, Dong-eui University, Busan 47227, Republic of Korea.
In the original publication [...
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China.
This study aimed to evaluate the efficacy of a novel three-dimensional (3D) spinal decompression and correction device in improving the in-brace correction and patient comfort level for adolescents with idiopathic scoliosis (AIS), and to assess the impact of the number of vertebrae involved in the scoliotic curve on the correction's effectiveness. A single-centre, single-blinded randomized controlled trial (RCT) was conducted in 110 AIS patients aged 10-18 years who were randomly allocated into four groups receiving 0-3 days of device intervention. Each session lasted for 30 min and was conducted twice daily.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!