Effect of lighting conditions on implantable collamer lens vault: Influence of anterior chamber and lens parameters.

Heliyon

Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.

Published: September 2024

Purpose: To investigate the change in the vault of the implantable collamer lens (ICL) under dark-to-light conditions and its association with anterior chamber and lens parameters in patients undergoing ICL surgery.

Methods: In 76 eyes from 40 patients, preoperative anterior chamber volume (ACV), pupil diameter (PD), anterior chamber angle, central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), axial length (AL), spherical equivalent (SE) and patient's age were collected. Postoperative vault, PD and LT were measured under dark and light conditions using anterior segment optical coherence tomography (CASIA2; TOMEY, Japan), and changes and lens displacement under dark-to-light conditions were calculated. Mixed-effects models were used to analyze the correlation between the vault change and the anterior chamber and lens parameters of all subjects and the high-vault subgroup.

Results: The vault under light condition (648.36 ± 304.47 μm) was significantly smaller compared to the vault under dark condition (708.89 ± 316.15 μm). In all patients, vault change increased with the increase of age, lens displacement and PD change; and increased with the decrease of ACV, LT change and baseline vault (under dark condition). In the high-vault subgroup, vault change increased with the increase of CCT, lens displacement and PD change; and increased with the decrease of ACV.

Conclusions: ICL vault changes significantly from dark to light, influenced by age, ACV, PD change, LT change, lens displacement, and baseline vault. A higher baseline vault is correlated with a larger LT change, affecting the levels of accommodation under dark-to-light transition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11420470PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e37895DOI Listing

Publication Analysis

Top Keywords

anterior chamber
20
lens displacement
16
change increased
16
vault
12
chamber lens
12
lens parameters
12
vault change
12
baseline vault
12
lens
10
change
10

Similar Publications

: This study evaluates the effectiveness of therapeutic keratoplasty for fungal keratitis and explores the diagnosis and management challenges of this infectious corneal disease. We retrospectively analyzed therapeutic keratoplasty cases at a tertiary hospital for keratitis when standard treatments failed. : Five cases of keratitis, unresponsive to typical antifungal treatments, required keratoplasty due to fast progression and diagnostic difficulties.

View Article and Find Full Text PDF

This study compares the long-term intraocular pressure (IOP)-lowering efficacy of standalone MINIject (iSTAR Medical, Belgium) suprachoroidal implantation and two iStent (Glaukos, CA, USA) trabecular bypass implantation using a systematic review and meta-analysis. Systematic review of standalone implantation of MINIject or iStent inject with at least 24 months of follow up. The mean and standard deviation of IOP and the number of IOP-lowering medications at baseline and at 24 months were extracted.

View Article and Find Full Text PDF

Speckle Strain Analysis of Left Ventricular Dysfunction in Paediatric Patients with Bicuspid Aortic Valve-A Pilot Study.

Children (Basel)

December 2024

Department of Neonatology, George Emil Palade Univ Med Pharm Sci&Technol. of Târgu Mureș, 540142 Târgu Mureș, Romania.

Background/objectives: Bicuspid aortic valve (BAV) is a prevalent congenital heart defect that continues to present a significant challenge in the management of paediatric patients. The assessment of left ventricle systolic function is typically conducted through the measurement of the left ventricular ejection fraction. Currently, left ventricle global longitudinal strain (LV GLS) is regarded as a more sensitive indicator, enabling the quantitative assessment of global and segmental ventricular function through the determination of myocardial deformation.

View Article and Find Full Text PDF

Purpose: To report a case of biopsy-proven sarcoidosis in a patient with panuveitis and a positive interferon-gamma release assay (IGRA) from a non-endemic tuberculosis (TB) country.

Methods: Case report.

Results: A 26-year-old male from the United Arab Emirates (UAE) presented with granulomatous panuveitis characterized by mutton-fat keratic precipitates, anterior chamber and vitreous cells, and retinal vasculitis.

View Article and Find Full Text PDF

Pulp chamber and root canal obliteration (PCO/RCO) presents a challenge for clinicians when nonsurgical endodontic treatment is indicated. Guided endodontics (GE) aims to precisely locate the root canal (RC) system while preserving as much pericervical dentin as possible. GE involves integrating cone-beam computed tomography (CBCT) of the affected tooth with a digital impression of the maxillary/mandibular arch, allowing for careful planning of the drilling path to the RC system through a three-dimensional (3D) static guide.

View Article and Find Full Text PDF