Quantitative evaluation of anti-biofilm cavitation activity seeded from microbubbles or protein cavitation nuclei by passive acoustic mapping.

Phys Med Biol

Institute of Biomedical Engineering, University of Oxford, Botnar Research Centre, Oxford, OX3 7LD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.

Published: September 2024

Bacterial biofilms represent a major challenge for effective antibiotic therapy as they confer physical and functional changes that protect bacteria from their surrounding environment. In this work, focused ultrasound in combination with cavitation nuclei was used to disrupt biofilms of Staphylococcus aureus and Pseudomonas aeruginosa, both of which are on the World Health Organization's priority list for new antimicrobial research. Approach: Single species biofilms were exposed to ultrasound (0.5 MHz centre frequency, 0.5-1.5 MPa peak rarefactional pressure, 200 cycle pulses, 5 Hz repetition frequency, 30 s duration), in the presence of two different types of cavitation nuclei. Quantitative passive acoustic mapping (PAM) was used to monitor cavitation emissions during treatment using a calibrated linear array. Main Results: It was observed that the cumulative energy of acoustic emissions during treatment was positively correlated with biofilm disruption, with differences between bacterial species attributed to differences in biofilm morphology. PCaN provided increased biofilm reduction compared to microbubbles due in large part to their persistence over the duration of ultrasound exposure. There was also good correlation between the spatial distribution of cavitation as characterized by PAM and the extent of biofilm disruption observed with microscopy. Significance: Collectively, the results from this work indicate the potential broad applicability of cavitation for eliminating biofilms of priority pathogens and the opportunity presented by Passive Acoustic Mapping for real-time monitoring of antimicrobial processes.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad7f1aDOI Listing

Publication Analysis

Top Keywords

cavitation nuclei
12
passive acoustic
12
acoustic mapping
12
emissions treatment
8
biofilm disruption
8
cavitation
7
quantitative evaluation
4
evaluation anti-biofilm
4
anti-biofilm cavitation
4
cavitation activity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!