A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

HR-pQCT cross-calibration using standard vs. Laplace-Hamming binarization approach. | LitMetric

HR-pQCT cross-calibration using standard vs. Laplace-Hamming binarization approach.

JBMR Plus

Bone Quality Research Lab, Department of Radiology and Biomedical Imaging, University of California, San Francisco, 185 Berry St., Suite 350, San Francisco, CA 94107, United States.

Published: October 2024

High-resolution peripheral quantitative computed tomography (HR-pQCT) has emerged as a powerful imaging technique for characterizing bone microarchitecture in the human peripheral skeleton. The second-generation HR-pQCT scanner provides improved spatial resolution and a shorter scan time. However, the transition from the first-generation (XCTI) to second-generation HR-pQCT scanners (XCTII) poses challenges for longitudinal studies, multi-center trials, and comparison to historical data. Cross-calibration, an established approach for determining relationships between measurements obtained from different devices, can bridge this gap and enable the utilization and comparison of legacy data. The goal of this study was to establish cross-calibration equations to estimate XCTII measurements from XCTI data, using both the standard and Laplace-Hamming (LH) binarization approaches. Thirty-six volunteers (26-85 yr) were recruited and their radii and tibiae were scanned on both XCTI and XCTII scanners. XCTI images were analyzed using the manufacturer's standard protocol. XCTII images were analyzed twice: using the manufacturer's standard protocol and the LH segmentation approach previously developed and validated by our team. Linear regression analysis was used to establish cross-calibration equations. Results demonstrated strong correlations between XCTI and XCTII density and geometry outcomes. For most microstructural outcomes, although there were considerable differences in absolute values, correlations between measurements obtained from different scanners were strong, allowing for accurate cross-calibration estimations. For some microstructural outcomes with a higher sensitivity to spatial resolution (eg, trabecular thickness, cortical pore diameter), XCTII standard protocol resulted in poor correlations between the scanners, while our LH approach improved these correlations and decreased the difference in absolute values and the proportional bias for other measurements. For these reasons and due to the improved accuracy of our LH approach compared with the standard approach, as established in our previous study, we propose that investigators should use the LH approach for analyzing XCTII scans, particularly when comparing to XCTI data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417609PMC
http://dx.doi.org/10.1093/jbmrpl/ziae116DOI Listing

Publication Analysis

Top Keywords

standard protocol
12
standard laplace-hamming
8
laplace-hamming binarization
8
second-generation hr-pqct
8
spatial resolution
8
establish cross-calibration
8
cross-calibration equations
8
xcti data
8
xcti xctii
8
images analyzed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!