A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring Anesthetic Depth Using the Patient State Index in Electroconvulsive Therapy Improves Seizure Quality. | LitMetric

Objectives: The determination of anesthetic depth has been used to assess the optimal moment for applying electrical stimuli in electroconvulsive therapy (ECT), as some of the anesthetics used can reduce its effectiveness. In this study, seizure quality was assessed using anesthetic depth measurement with the patient state index (PSI).

Methods: A prospective experimental study was conducted with a control group, including a sample of 346 stimulations (PSI=134; Control=212) in 51 patients admitted and diagnosed with major depressive disorders. Seizure adequacy variables (seizure time in electroencephalogram [EEG] and motor activity, visual evaluation of the EEG, ECT-EEG parameter rating scale [EEPRS], seizure concordance, central inhibition, automated parameters, and autonomic activation) were assessed using linear mixed-effects models for continuous variables and generalized linear mixed-effects models for dichotomous variables.

Results: The PSI group required lower stimulation energy. The use of the PSI was associated with longer seizure time, both motor and electroencephalographic, higher quality of the EEG recording, better seizure concordance, and higher values for the automated parameters of maximum sustained coherence and time to peak coherence.

Conclusions: The use of the PSI to measure anesthetic depth may reduce the electrical stimulus charge required and improve seizure quality in ECT modified with propofol.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2398-7693DOI Listing

Publication Analysis

Top Keywords

anesthetic depth
16
seizure quality
12
patient state
8
electroconvulsive therapy
8
seizure
8
seizure time
8
seizure concordance
8
automated parameters
8
linear mixed-effects
8
mixed-effects models
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!