Inhaled dose is crucial for accurately assessing exposure to air pollution, determined by pollutant concentration and minute ventilation (VE). However, the VE predictive models and its application to assess the health effects of air pollution are still lacking. In this study, we developed VE predictive models using machine learning techniques, utilizing data obtained from eighty participants who underwent a laboratory cardiopulmonary exercise test (CPET). VE predictive models were developed using generalized additive model (GAM), random forest model (RF) and extreme gradient boosting (XGBoost) and analyzed for explanation of input variables. The Random Forest model, cross-validated, exhibited outstanding performance with an R of 0.986 and a MAE of 1.816 L/min. The median difference between the measured VE and the predicted VE was 0.18 L/min, and the median difference between the black carbon (BC) inhaled dose based on predicted VE and measured VE was 0.02 ng. Employing explainable machine learning, the results showed that metabolic equivalent (METs), heart rate, and body weight are the three top important variables, emphasizing the significance of incorporating METs variables when constructing VE models. Through multiple linear regression models and an adjusted stratified analysis model, the significant adverse association between BC concentration and inhaled dose on diastolic blood pressure (DBP) was only observed in female. The disparity in the effect of BC inhaled dose compared to BC concentration on DBP reached up to 115 %. This study is the first to explore the ability of different machine learning algorithms to construct VE prediction models and directly apply the models to assess health effects of an example pollutant. This study contributes to the accurate assessment of air pollution exposure leveraging wearable devices, an approach useful for environmental epidemiology studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2024.176415DOI Listing

Publication Analysis

Top Keywords

inhaled dose
20
air pollution
12
predictive models
12
machine learning
12
minute ventilation
8
wearable devices
8
assess health
8
health effects
8
random forest
8
forest model
8

Similar Publications

To gain a comprehensive understanding of the effects of air pollution on human health, it is imperative to assess exposure at an individual level. This necessitates the use of personal monitoring equipment that can record exposure in real-time while simultaneously capturing relevant biometric data and the activities being undertaken by the individual. The dataset presented herein encompasses data from five distinct sources, collected in Ljubljana, Slovenia: (a) Questionnaire filled out by all participants for general information, i.

View Article and Find Full Text PDF

Background: Laparoscopic radical gastrectomy has been reported to be associated with substantial trauma and pain. This study compared the impact of ultrasound-(US)-guided, bilateral, double-injection intertransverse process block (ITPB) on postoperative analgesia with subcostal transversus abdominis plane block (TAPB) in patients who were undergoing laparoscopic radical gastrectomy.

Methods: Sixty-two patients who were undergoing laparoscopic radical gastrectomy surgery under general anesthesia were included.

View Article and Find Full Text PDF

ObjectivesPatient perception of treatment effectiveness is key to optimizing adherence. This is potentially impacted by color, yet no such studies have been conducted in asthma. This study assessed the influence of pink vs.

View Article and Find Full Text PDF

Background: Spray drying, whilst a popularly employed technique for powder formulations, has limited applications for large-scale proliposome manufacture.

Objectives: Thus, the aim of this study was to investigate spray drying parameters, such as inlet temperature (80, 120, 160, and 200 °C), airflow rate (357, 473, and 601 L/h) and pump feed rate (5, 15, and 25%), for individual carbohydrate carriers (trehalose, lactose monohydrate (LMH), and mannitol) for 24 spray-dried (SD) formulations (F1-F24).

Methods: Following optimization, the SD parameters were trialed on proliposome formulations based on the same carriers and named as spray-dried proliposome (SDP) formulations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!