Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Biological drug substance (DS) is often frozen to enhance storage stability, prolong shelf life, and increase flexibility during manufacturing. However, the freezing and thawing (F/T) of bulk DS at the manufacturing scale can impact product quality as a result of various critical conditions, including cryo-concentration during freezing, which are influenced, among other things, by product-independent process parameters (e.g., container type, fill level, F/T equipment, and protocols). In this article, we report the optimization of two major methodologies to study product-independent process parameters in DS bottles at the manufacturing scale, namely the recording of temperature profiles and liquid sampling after thawing to quantify the concentration gradients in the solution. We report experimentally justified measuring positions for temperature recordings, especially for the selection of the last point to freeze position, and highlight the implementation of camera-assisted inspection to determine the last point to thaw and the actual thawing time. In particular, we provide, for the first time, a detailed description of the technical implementation of these two measuring set-ups. Based on the reported case studies, we recommend choosing relevant measuring positions as a result of initial equipment characterization, resulting in a resource-conscious study set-up.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417747 | PMC |
http://dx.doi.org/10.3390/mps7050068 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!