In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK 'acceptable' avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images ( = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1-16) and in the second EQA distribution was 7 (0-16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = -0.734, = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417764PMC
http://dx.doi.org/10.3390/ijns10030060DOI Listing

Publication Analysis

Top Keywords

dbs diameter
12
minimum standard
12
dbs
9
dried blood
8
blood spot
8
newborn screening
8
minimum acceptable
8
acceptable dbs
8
nbs laboratories
8
number specimens
8

Similar Publications

Introduction: Intracranial hemorrhage (ICH) in functional neurosurgery is a relatively rare but serious complication. One of the possible risk factors related to ICH is the number of trajectories made for microelectrode recording (MER). Authors who solely rely on macrostimulation using macroelectrodes argue that the incidence of ICH is much lower while maintaining good clinical efficacy of deep brain stimulation (DBS).

View Article and Find Full Text PDF

Untargeted metabolomics UHPLC-HRMS workflows typically employ narrowbore 2.1-mm inner diameter (i.d.

View Article and Find Full Text PDF

Minitablets have been extensively studied in recent years as a convenient pediatric form because they allow successful administration even in very young children. Their advantages include easy dose adjustment by multiplication of single units as well as the possibility of drug release modification by coating or forming matrix systems. The aim of this study was to demonstrate the possibility of the formulation of prolonged-release minitablets with bromhexine hydrochloride (BHX) and bisoprolol fumarate (BFM) dedicated to pediatric patients.

View Article and Find Full Text PDF

Effect of neuromodulation for chronic pain on the autonomic nervous system: a systematic review.

BJA Open

September 2024

STIMULUS Research Group, Cluster Neurosciences, Center for Neurosciences (C4N) and Pain in Motion (PAIN) Research Group, Department of Physiotherapy, Human Physiology and Anatomy, Faculty of Physical Education and Physiotherapy, Vrije Universiteit Brussel, Brussels, Belgium.

Article Synopsis
  • There is increasing interest in neuromodulation techniques, like spinal cord and peripheral nerve stimulation, as alternatives for managing chronic pain, focusing on their effects on the autonomic nervous system (ANS).
  • A systematic review analyzed 43 studies from various databases, assessing how neuromodulation impacts the ANS in chronic pain patients, with cardiovascular parameters being the most common outcome measured.
  • Results showed a variety of ANS function indicators, emphasizing the need for better understanding of neuromodulation's role in chronic pain treatment and its interaction with the ANS.
View Article and Find Full Text PDF

In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!