A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Level of Compliance with Spanish Guideline Recommendations in the Management of Asthma. | LitMetric

Objective: To describe the clinical management of asthmatic patients and the level of compliance with the (GEMA, Spanish Guidelines for Asthma Management) in the influential al area of Virgen de la Victoria University Hospital, Málaga (Spain).

Materials And Methods: Descriptive, cross-sectional study in asthma patients from the Virgen de la Victoria University Hospital influential area, Málaga (Spain). Asthma Control Test (ACT) results, demographic and clinical characteristics, and GEMA indicators of quality asthma care were obtained from each participating patient.

Results: Two hundred and eighty-eight patients (64.2% woman, mean age 48.6 years) were included in the study. The evaluation of the level of compliance with the GEMA quality indicators showed that in 20.8% of the patients the diagnosis of asthma was confirmed by spirometry and bronchodilator test, and 52.5% of the patients with suspicion of allergic asthma performed a sensitization test. Among the smoker patients, 76.3% were recommended to stop smoking; 14.2% of the patients received a paper-based educational plan. Regarding asthma treatment, 92.3% of patients with persistent asthma received inhaled glucocorticoids (IGC). IGC and LABA were the most common treatments for asthma, used in combination (ICG + LABA) in 139 (48.3%) patients; 32.6% discontinued SABA treatment during the study period. Asthma was well controlled in 54.9% of the patients (ACT score ≥20), and 13.9% of the patients registered exacerbations during the previous year with a mean (SD) of 1.38 (0.74) events.

Conclusion: Most of the GEMA quality indicators of asthma care are not followed in real-world clinical practice. Specialists select the best option among the available treatments but there is an unmet need for training plans in other relevant aspects, such as diagnosis and/or disease monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414629PMC
http://dx.doi.org/10.2147/JAA.S433291DOI Listing

Publication Analysis

Top Keywords

level compliance
12
asthma
12
patients
11
compliance gema
8
influential area
8
virgen victoria
8
victoria university
8
university hospital
8
asthma care
8
gema quality
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!