Performance verifications of laser tracker systems (LTSs) often rely on calibrated length artifacts that are 2.3 m in length or more, as specified in International Standards Organization (ISO) and American Society of Mechanical Engineers (ASME) standards. The 2.3 m length is chosen as the minimum length that will sufficiently expose inaccuracy in LTSs. Embodiment of these artifacts often comes in the form of scale bars, fixed monuments, or a laser rail. In National Institute of Standards and Technology (NIST) Internal Report (IR) 8016, which was published in 2014 and discusses interim testing of LTSs, it was shown that a scale bar with three nests spaced 1.15 m apart was sufficient for exposing errors in LTSs. In that case, the LTS was placed symmetrically with respect to the scale bar so that both a 2.3 m symmetrical length and a 1.15 m asymmetrical length were presented to the LTS. This paper will evaluate whether a scale bar that is only 1.15 m in length can sufficiently expose errors within the LTS when it is stitched together to create a 2.3 m long test length.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374359 | PMC |
http://dx.doi.org/10.6028/jres.125.016 | DOI Listing |
Behav Sci (Basel)
December 2024
Department of Psychology, Bar-Ilan University, Ramat Gan 5290002, Israel.
In this study, we applied the actor-partner interdependence model (APIM) to explore the associations between personality traits (Big Five) and psychological flexibility, on the one hand, and depression and anxiety, on the other hand, among patients with cancer and their spouses. Method: Forty-six patient-spouse dyads (N = 92) completed the anxiety and depression scales from the Patient-Reported Outcomes Measurement Information System (PROMIS), the ten-item personality inventory (TIPI), and the psychological flexibility scale (AAQ-2). Multilevel APIM models, adjusted for multiple testing, showed that neuroticism and psychological flexibility had actor effects on patients' depression and anxiety.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
January 2025
Dental Materials Unit, Center for Dental Medicine, Clinic for Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland.
The purpose of this study was to evaluate the characteristics of the ceramic bonding to cobalt-chromium (Co-Cr) alloys fabricated by casting, milling, and additive manufacturing, compared with zirconia and nickel-chromium. One hundred specimens (N = 100), prepared with the dimensions of 25 × 3 × 0.5 mm, were assigned to five groups (n = 20): presintered milled Co-Cr (Group M), additively manufactured Co-Cr (Group SLM), cast Co-Cr (Group C), presintered zirconia (Group Zi), and cast Ni-Cr (Group Ni).
View Article and Find Full Text PDFSci Rep
January 2025
Department of Energy Resources, University of Stavanger, Stavanger, Norway.
Salt caverns are widely regarded as a suitable option for the underground storage of hydrogen. However, an accurate assessment of the hydrogen leakage through the walls of salt caverns into the surrounding formations remains crucial. In this work, the flow of hydrogen into the surrounding formation is evaluated by assuming that salt rock consists of bundles of tortuous nano-capillary tubes.
View Article and Find Full Text PDFJ Fam Psychol
January 2025
Department of Social and Health Sciences, Bar-Ilan University.
Biomimetics (Basel)
December 2024
Department of Chemistry, Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel.
Developing a durable multifunctional superhydrophobic coating on polymeric films that can be industrially scalable is a challenge in the field of surface engineering. This article presents a novel method for a scalable technology using a simple single-step fabrication of a superhydrophobic coating on polymeric films that exhibits excellent water-repelling and UV-blocking properties, along with impressive wear resistance and chemical robustness. A mixture of titanium precursors, tetraethylorthosilicate (TEOS), hydrophobic silanes and silica nano/micro-particles is polymerized directly on a corona-treated polymeric film which reacts with the surface via siloxane chemistry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!