AI Article Synopsis

Article Abstract

A male patient in his 50s presented to the emergency department with a three-day history of shortness of breath, New York Heart Association class IV, and oxygen desaturation. His physical examination revealed a large volume radial pulse with bibasal crepitation in the lungs and a soft diastolic murmur in the aortic area on auscultation of his heart. He was managed on the line of decompensated heart failure. Transthoracic echocardiography showed a dissection flap in the ascending aorta with acute severe aortic regurgitation. A subsequent urgent CT angiography of the whole aorta confirmed a complex type A aortic dissection with an aneurysmal ascending aorta. An emergency type A aortic dissection repair (modified Bentall's procedure) was done. The patient made a good recovery, was discharged successfully 2 weeks after the procedure and was doing well on postoperative follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bcr-2024-261556DOI Listing

Publication Analysis

Top Keywords

aortic dissection
12
heart failure
8
ascending aorta
8
type aortic
8
aortic
5
silent stealth
4
stealth painless
4
painless aortic
4
dissection
4
dissection masquerading
4

Similar Publications

Prognostic Value of D-Dimer in Acute Type A Aortic Dissection and Intramural Hematoma: Observations from the Acute Aortic Syndrome Group of the Registry of Acute Non-Traumatic Chest Pain in China.

J Am Heart Assoc

January 2025

Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, and The Key Laboratory of Cardiovascular Remodeling-related Diseases, Ministry of Education, and Beijing Institute of Heart Lung and Blood Vessel Disease Beijing China.

Background: Acute type A aortic dissection (AAD) and acute type A intramural hematoma (AIMH) are life-threatening conditions with high mortality rates, and prognostic indicators are critical for guiding urgent treatment decisions. We assessed the prognostic significance of admission D-dimer levels in patients with AAD and AIMH.

Methods And Results: The prospective, multicenter, observational study in China recruited participants from 2013 to 2019.

View Article and Find Full Text PDF

Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error.

View Article and Find Full Text PDF

Development and Validation of a Diagnostic Model for Stanford Type B Aortic Dissection Based on Proteomic Profiling.

J Inflamm Res

January 2025

Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, People's Republic of China.

Purpose: Stanford Type B Aortic Dissection (TBAD), a critical aortic disease, has exhibited stable mortality rates over the past decade. However, diagnostic approaches for TBAD during routine health check-ups are currently lacking. This study focused on developing a model to improve the diagnosis in a population.

View Article and Find Full Text PDF

Type B aortic dissection (TBAD) represents a serious medical emergency with up to a 50% associated 5-year mortality caused by thoracic aorta, dissection-associated aneurysmal (DAA) degeneration, and rupture. Unfortunately, conventional size-related diagnostic methods cannot distinguish high-risk DAAs that benefit from surgical intervention from stable DAAs. Our goal is to use DAA stiffness measured with magnetic resonance elastography (MRE) as a biomarker to distinguish high-risk DAAs from stable DAAs.

View Article and Find Full Text PDF

We report a case of mesenteric ischemia after thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection performed at a different institution. Computed tomography angiography findings indicated that the previous TEVAR had been deployed distally into the false lumen. To mitigate this, a large fenestration was created between the false lumen and true lumen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!