AI Article Synopsis

  • Bromochloro alkanes (BCAs) are newly identified flame retardants similar to other Persistent Organic Pollutants and have been found in environmental samples for the first time, yet no standard methods for their quantification exist.
  • This study involves the synthesis of 16 custom standards to explore quantification strategies for BCAs in indoor dust, achieving an average measurement accuracy of 81% and meeting EU accuracy criteria in 89% of cases during fortification trials.
  • Despite these advancements, applying the quantification method to actual dust samples showed a low correlation with the prototype standards, highlighting the need for more diverse mixture standards for reliable BCA quantification in environmental samples.

Article Abstract

Bromochloro alkanes (BCAs) are a class of flame retardants similar in structure to polychlorinated alkanes (PCAs), which are the major component of short-chain chlorinated paraffins (SCCPs) listed as Persistent Organic Pollutants under the Stockholm Convention. BCAs have recently been detected for the first time in environmental samples. Due to the complete lack of commercially available analytical standards, no method for quantifying BCAs has been reported to date. In this study, 16 custom-synthesised standards with mixed bromine and chlorine halogenation and carbon chain lengths ranging from C to C were characterized by liquid chromatography and Orbitrap high-resolution mass spectrometry and used to assess the applicability of pattern deconvolution quantification strategies for BCAs in indoor dust. Br and Cl BCAs were detected as [M + Cl] adduct ions among the C to C standards, as well as numerous PCA homologues. After applying correction factors to account for the presence of PCAs in the standards, triplicate fortification experiments using varied halogenation composition and concentration determined an average measurement accuracy of 81% over the carbon chain lengths studied and coefficient of variance ≤20% between replicates. Overall, approximately 89% of the ΣBCA concentrations quantified in the fortification trials met the European Union Reference Laboratory's accuracy acceptability criteria recommended for PCAs, between 50 and 150%. Application of the BCA pattern deconvolution quantification procedure to seven representative indoor dust samples from the United States of America revealed a low correlation between the homologue distribution in the samples and the prototype standards (R ≤ 0.40), which precluded reliable quantification. This study indicates that pattern deconvolution is an appropriate strategy for quantifying BCAs in environmental samples, but that a large set of appropriate mixture standards will be required before more reliable estimates of BCA concentrations can be achieved in indoor dust.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2024.143370DOI Listing

Publication Analysis

Top Keywords

pattern deconvolution
16
indoor dust
16
dust samples
8
bcas detected
8
environmental samples
8
quantifying bcas
8
carbon chain
8
chain lengths
8
deconvolution quantification
8
bcas
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!