A robotic system for manipulating a flexible endoscope in surgery can provide enhanced accuracy and usability compared to manual operation. However, previous studies require large-scale, complex hardware systems to implement the rotational and translational motions of the soft endoscope cable. The conventional control of the endoscope by actuating the endoscope handle also leads to undesired slack between the endoscope tip and the handle, which becomes more problematic with long endoscopes such as a colonoscope. This study proposes a compact quad-roller friction mechanism that enables rotational and translational motions triggered not from the endoscope handle but at the endoscope tip. Controlling two pairs of tilted rollers achieves both types of motion within a small space. The proposed system also introduces an unsynchronized motion strategy between the handle and tip parts to minimize the robot's motion near the patient by employing the slack positively as a control index. Experiments indicate that the proposed system achieves accurate rotational and translational motions, and the unsynchronized control method reduces the total translational motion by up to 88% compared to the previous method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/24699322.2024.2404695 | DOI Listing |
Cureus
December 2024
Orthopaedic Surgery, Showa University School of Medicine, Tokyo, JPN.
Introduction This study evaluated hip joint dynamic instability in patients with non-traumatic osteonecrosis of the femoral head (ONFH) with extensive lesions, who had undergone anterior rotational osteotomy (ARO) and high-degree posterior rotational osteotomy (HDPRO), based on the femoral head translation observed by computed tomography (CT) at 0° and 45° hip flexion. Materials and methods Medical records of patients who had undergone transtrochanteric rotational osteotomy for non-traumatic ONFH were retrospectively reviewed to identify patients who had undergone CT examinations six weeks post-operatively. In all, 64 hips (60 patients; 19 men and 41 women), comprising 36 hips treated with HDPRO and 28 hips treated with ARO, respectively, were included.
View Article and Find Full Text PDFRev Port Cardiol
January 2025
Faculdade de Medicina, Universidade de Coimbra, Coimbra, Portugal; Serviço de Cardiologia, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal; Coimbra Institute for Clinical and Biomedical Research (iCBR), Coimbra, Portugal.
Introduction And Objectives: Rotational atherectomy (RA) is widely used for the management of calcified coronary stenoses. However, there is limited data on its use, trends, and outcomes. We sought to report our twelve-year experience with RA and explore the trends and outcomes of percutaneous coronary intervention (PCI) with this device.
View Article and Find Full Text PDFJ Ren Care
March 2025
Faculty of Sciences Semlalia, Laboratory of Pharmacology, Neurobiology, Anthropobiology and Environment, Cadi Ayyad University, Marrakech, Morocco.
Background: Arteriovenous fistula self-care behaviours in patients receiving haemodialysis are essential to maintain patency of vascular access and prevent its life-threatening complications. Assessing arteriovenous fistula self-care behaviours in patients receiving haemodialysis requires a reliable and valid tool.
Objective: The aim of this study was to adapt and translate the Portuguese scale for the assessment of self-care behaviours of arteriovenous fistula in patients receiving haemodialysis into the Moroccan dialect and evaluate its psychometric properties in the Moroccan context.
Sci Rep
January 2025
Research and Development, Aesculap AG, Tuttlingen, Germany.
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Biomedical Engineering, The Ohio State University, Columbus, OH, United States of America.
Traumatic optic neuropathy (TON) is a common cause of irreversible blindness following head injury. TON is characterized by axon damage in the optic nerve followed by retinal ganglion cell death in the days and weeks following injury. At present, no therapeutic or surgical approach has been found to offer any benefit beyond observation alone.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!