AI Article Synopsis

  • - This study aimed to assess the incidence and risk factors of medical device-related pressure injuries (MDRPIs) in newborns in the neonatal intensive care unit (NICU), observing 116 infants over a year.
  • - Results showed a 35.3% incidence of MDRPIs, with significant contributions from NIRS probes (38.1%) and respiratory devices (33.5%), predominantly affecting areas like the forehead and limbs.
  • - The findings highlighted gestational age as a key risk factor for developing MDRPIs, emphasizing the need for NICU nurses to implement preventive strategies based on these risks.

Article Abstract

Aim: This study was conducted to investigate the incidence of medical device-related pressure injuries (MDRPIs) and the risk factors influencing their occurrence in the neonatal intensive care unit (NICU).

Method: This study is a prospective, descriptive study. The research was conducted with 116 newborns between June 1, 2022, and June 1, 2023. Newborns who stayed in the neonatal intensive care unit for at least 24 h were observed daily for medical device-related pressure injuries under and around each medical device throughout their stay in the intensive care unit. The "Case Report Form," "MDRPIs Monitoring Form," "Braden Q scale for children," National Pressure Injury Advisory Panel (NPIAP) Pressure Grading, and Glasgow Coma Scale were used in the research.

Results: The incidence of medical device-related pressure injuries is 35.3 % (41/116). It was found that 38.1 % (16/42) of medical device-related pressure injuries developed due to Near-Infrared Spectroscopy (NIRS) probes, and 33.5 % (14/42) developed due to medical devices related to the respiratory system. In terms of anatomical location, 38.1 % occurred on the forehead, and 23.8 % on the arm/leg. The difference between birth weight, gestational age, development of MDRPIs in newborns receiving sedation and inotropes was found to be statistically significant. Regression analysis identified gestational age (p = 0.040, OR = 0.795, 95%CI = [0.632-1.000]) as an independent risk factor for the occurrence of medical device-related pressure injuries.

Conclusions: The incidence of medical device-related pressure injuries in newborns was relatively high in this study, with gestational age being the most significant risk factor for MDRPIs formation. It is crucial for neonatal intensive care nurses to consider associated risk factors while providing newborn care and implement appropriate preventive measures to reduce the incidence of MDRPIs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtv.2024.09.005DOI Listing

Publication Analysis

Top Keywords

medical device-related
28
device-related pressure
28
pressure injuries
24
incidence medical
16
intensive care
16
risk factors
12
neonatal intensive
12
care unit
12
gestational age
12
pressure
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!