Repeated lyophilization: A neo-method for urine-based reference materials preparation.

J Pharm Biomed Anal

Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Academy of Forensic Science, Shanghai 200063, China. Electronic address:

Published: January 2025

In urine drug testing, a cut-off value is often imposed to determine whether the sample is negative or positive. A matrix containing a reference substance helps counteract the adverse effects of the urine matrix across different laboratories to improve the consistency of final results. However, as a biological matrix, urine is prone to corruption and other problems that make it difficult to use as a reference sample. In this study, morphine, nitrazepam, lorazepam, buprenorphine, zolpidem, midazolam, diazepam, and clozapine commonly used in clinical practice were selected as target analytes, and the preparation process was further optimized to repeated lyophilization, in order to obtain more effective, stable, and accurate urine matrix reference materials (mRMs). The appropriate urine density (1.010-1.017 kg/m) for preparing lyophilized samples was investigated through density determination. Conducting repeated lyophilizations resulted in a denser powder with reduced susceptibility to collapse and improved the quality of lyophilized urine samples. Lyophilized urine mRMs could be stored at room temperature for one month or under refrigeration conditions (4 ℃) for six months.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2024.116481DOI Listing

Publication Analysis

Top Keywords

repeated lyophilization
8
reference materials
8
matrix reference
8
urine matrix
8
lyophilized urine
8
urine
7
lyophilization neo-method
4
neo-method urine-based
4
reference
4
urine-based reference
4

Similar Publications

This study evaluated the efficacy and safety of Intralesional Acyclovir in the treatment of recalcitrant palmoplantar and ungual warts in 14 patients(7 male and 7 female) of mean age 24.5 +- 8.19 years.

View Article and Find Full Text PDF

Plum pox virus (PPV) is the etiological agent of sharka, the most important viral disease of stone fruit worldwide. In this study, a one-step reverse transcription real-time PCR test (RT-qPCR) was modified and translated as a one-step RT-droplet digital PCR (RT-ddPCR) for sensitive, direct, and accurate detection and quantification of PPV. The modified RT-qPCR and RT-ddPCR PPV detection tests were validated using both plant purified total RNA (TRNA) and crude extract as templates.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the safety and effects of a canine-specific albumin (CSA) product administered repeatedly to healthy Beagles, focusing on any adverse reactions and changes in serum albumin concentrations and colloid osmotic pressure (COP).
  • Six healthy adult Beagles were given 1 g/kg of CSA via intravenous infusion on three different days, with monitoring for any negative side effects and measuring serum albumin and COP before and after each infusion.
  • Results showed minimal adverse effects (one instance of vomiting) and significant increases in serum albumin and COP levels after each infusion, indicating that the CSA product is safe and effective for enhancing these blood parameters in dogs.
View Article and Find Full Text PDF

Reversibly Compressible Silanated Cellulose Nanofibril Aerogel for Triboelectric Taekwondo Scoring Sensors.

Small

December 2024

National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Daejeon, Yuseong-gu, 34141, Republic of Korea.

The integration of bio-based materials into triboelectric nanogenerators (TENGs) for energy harvesting from human body motions has sparked considerable research attention. Here, a silanated cellulose nanofibril (SCNF) aerogel is reported for structurally reliable TENGs and reversely compressible Taekwondo scoring sensors under repeated impacts. The preparation of the aerogel involves silanizing cellulose nanofibers (CNFs) with vinyltrimethoxysilane (VTMS), following by freeze-drying and post-heating treatment.

View Article and Find Full Text PDF

Repeated lyophilization: A neo-method for urine-based reference materials preparation.

J Pharm Biomed Anal

January 2025

Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Academy of Forensic Science, Shanghai 200063, China. Electronic address:

In urine drug testing, a cut-off value is often imposed to determine whether the sample is negative or positive. A matrix containing a reference substance helps counteract the adverse effects of the urine matrix across different laboratories to improve the consistency of final results. However, as a biological matrix, urine is prone to corruption and other problems that make it difficult to use as a reference sample.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!