Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Due to anatomical changes between pre-planning and implantation, there exists a need for tools that can streamline the adjustment of needle and seed configurations in low dose rate brachytherapy for prostate cancer. Specifically, upon taking a second ultrasound on the day of treatment, the distribution of seeds and needles will differ drastically from the original plan. Clinics that employ this method must then spend time and resources to generate a workflow to manipulate the original configuration to the new configuration. ONCOSEED extracts data from VariSeed treatment plans, calculating a labor score (LScore) to optimize adjustments to needle configurations. A case study of three simulated VariSeed treatment plans was used to compare the ONCOSEED software to the manual method of generating a workflow. In the same method that was used at the authors' clinic, several assistants annotated by hand the original plan to convert it to the new plan. The time taken to do so was recorded and compared to the runtime of the software when generating a workflow for the same plan. Results showed that ONCOSEED was on average 28 times faster than generating a workflow by hand. ONCOSEED enhances the efficiency of seed replacement in LDR brachytherapy, promoting the adoption of adaptive brachytherapy practices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11409035 | PMC |
http://dx.doi.org/10.1016/j.tipsro.2024.100273 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!