A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of surface micro-roughness and adaptation of titanium and cobalt chrome implant abutment fabricated by selective laser melting and conventional techniques. | LitMetric

Purpose: The objective of this study was to assess the surface micro-roughness and abutment adaptation of selective laser melting (SLM) implant abutments in comparison to cast and machined implant abutments.

Methods: Forty abutment specimens were divided equally into four groups according to the fabrication technique as follows (n = 10), Machined Ti alloy abutments (Control), Cast CoCr abutments, SLM-CoCr abutments, and SLM-Ti alloy abutments. Forty internal connection implants (Ø 4.0 ×10 mm, Superline™, Dentium Co., Seoul, Korea) were mounted in clear acrylic resin. Fabricated abutments were assessed for surface micro-roughness using a 3D optical noncontact surface microscope. Vertical and horizontal adaptation of the abutment with implant interface was assessed by using Bruker micro-CT. Data was assessed using analysis of variance and Tukey post hoc comparison tests for all the variables except vertical misfit was assessed using Kruskal-Wallis test. Pearson correlation was used to assess dependence between independent variable (surface roughness) and dependent variables (Horizontal misfit and vertical misfit).

Results: SLM-Ti abutments showed significantly rougher surface (p < 0.05) among the study groups. While SLM-CoCr abutments were smoother than Cast abutments with mean Ra of 1.30 ± 0.11 and 1.58 ± 0.17 μm, respectively (p < 0.05). For abutment adaptation, SLM-Ti abutments showed the highest horizontal misfit among the groups (p < 0.05). While, SLM-CoCr abutments (29.24 ± 11.11 μm) showed comparable (p > 0.05) horizontal misfit results with Cast (26.08 ± 3.93 μm) and machined (26.45 ± 7.33 μm) abutments. Comparable (p > 0.05) vertical misfit values between Cast CoCr (487.01 ± 40.34 μm), SLM-CoCr (358.38 ± 114.93 μm) and SLM-Ti (299.85 ± 172.88 μm) abutments were observed. A positive correlation was found between the surface roughness of the mating surfaces and abutment adaptation.

Conclusion: SLM CoCr abutments exhibited low roughness and comparable abutment adaptation (vertically and horizontally) than cast (control) abutments. Therefore, SLM CoCr abutments should be clinically investigated as potential implant abutments for clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cid.13390DOI Listing

Publication Analysis

Top Keywords

surface micro-roughness
12
selective laser
8
laser melting
8
alloy abutments
8
abutments
7
surface
5
comparison surface
4
micro-roughness adaptation
4
adaptation titanium
4
titanium cobalt
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!