A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microdialysis-integrated HPLC system with dual-electrode detection using track-etched membrane electrodes for in vivo monitoring of dopamine dynamics. | LitMetric

A capillary high-performance liquid chromatography (HPLC) system equipped with a dual-electrode detector utilizing track-etched membrane electrodes (TEMEs) was combined with a microdialysis sampling setup. The electrochemical detector benefits from the high electrolysis efficiency of TEMEs, allowing for calibration-free coulometric detection and simplifying data analysis to determine the dopamine recovery through a dialysis probe. Additionally, this system was used for in vivo monitoring of dopamine in the right striatum of a mouse brain. Temporal changes in dopamine levels, including an exponential decay immediately after the dialysis probe insertion and an excess release of dopamine induced by a high concentration of potassium ions, confirmed the system's proper operation. Furthermore, subsequent measurements following the intraperitoneal injection of mirtazapine showed no increase in dopamine levels in the right dorsal striatum. The dual-electrode system displayed characteristic dopamine detection behavior, with anodic and cathodic peak pairs indicative of reversible electrochemical reactions. This capability facilitated the identification of the dopamine peak within the complex chromatogram of the mouse brain dialysate. The consistency between dopamine collection efficiency from standard solutions and dialysate indicated the absence of interfering electroactive substances overlapping with the dopamine peak in the chromatogram. This integrated analysis system successfully tracked temporal fluctuations in dopamine concentration within the mouse brain.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2024.124318DOI Listing

Publication Analysis

Top Keywords

mouse brain
12
dopamine
11
hplc system
8
track-etched membrane
8
membrane electrodes
8
vivo monitoring
8
monitoring dopamine
8
dialysis probe
8
dopamine levels
8
dopamine peak
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!