AI Article Synopsis

  • - The study evaluated the antibacterial effects of a high-voltage prick electric field (HVPEF) on gelatin and various food items, revealing a 98% mortality rate on gelatin at 13 kV for 15 minutes, with a gradual decrease in bacterial survival over time.
  • - HVPEF treatment resulted in significant cellular damage, including compromised cell membranes and disrupted nucleic acids, which increased reactive oxygen species (ROS) levels and ultimately led to cell death due to DNA damage.
  • - In terms of food safety, HVPEF drastically reduced bacteria on food surfaces (e.g., 91% on salmon), while maintaining the color and texture of the products; it also contributed to reduced spoilage indicators, potentially extending

Article Abstract

The present study assesses the antibacterial effect of a high-voltage prick electric field (HVPEF) on on gelatin plates and selected food systems. The results showed that were susceptible to HVPEF treatment, with a mortality rate of 98% on the gelatin plate at 13 kV for 15 min. The survival rate of decreased linearly with time and then stabilized after a sharp decline. The morphological change and the loss of internal nucleic acids and proteins suggest that the cell membrane was damaged by HVPEF, appearing more permeable and less fluid. Compared with the untreated group, both reactive oxygen species (ROS) and malondialdehyde increased significantly in the treated groups. Flow cytometry results suggest that DNA was severely damaged, which led to cell death, as shown by the elevated levels of intracellular ROS and lipid peroxidation. The death rate of on the food surface significantly rose with the increase of HVPEF intensity, reaching 91 ± 1.6% (salmon), 88.2 ± 2.2% (chicken breast), 72.9 ± 2.7% (sausage), and 66.9 ± 1.6% (steak), respectively, at 14 kV for 30 min. HVPEF resulted in no significant change in color or texture; the changes in total viable count and pH were less significant than in the untreated group. Finally, HVPEF treatment led to lower levels of total volatile base nitrogen and thiobarbituric acid reactive substances in chicken breasts, which potentially contributes to longer shelf life.

Download full-text PDF

Source
http://dx.doi.org/10.1089/fpd.2024.0054DOI Listing

Publication Analysis

Top Keywords

high-voltage prick
8
prick electric
8
electric field
8
gelatin plates
8
plates selected
8
selected food
8
food systems
8
hvpef treatment
8
untreated group
8
hvpef
6

Similar Publications

Article Synopsis
  • - The study evaluated the antibacterial effects of a high-voltage prick electric field (HVPEF) on gelatin and various food items, revealing a 98% mortality rate on gelatin at 13 kV for 15 minutes, with a gradual decrease in bacterial survival over time.
  • - HVPEF treatment resulted in significant cellular damage, including compromised cell membranes and disrupted nucleic acids, which increased reactive oxygen species (ROS) levels and ultimately led to cell death due to DNA damage.
  • - In terms of food safety, HVPEF drastically reduced bacteria on food surfaces (e.g., 91% on salmon), while maintaining the color and texture of the products; it also contributed to reduced spoilage indicators, potentially extending
View Article and Find Full Text PDF

Coenzyme Q10 (CoQ10) is an essential medicinal ingredient. In this study, we obtained a high-yielding mutant strain of CoQ10, VK-2-3, by subjecting V-0 (V-0) to a C heavy ion beam and high-voltage prick electric field treatment. To investigate the mutation mechanism, the complete genomes of VK-2-3 and V-0 were sequenced.

View Article and Find Full Text PDF

Staphylococcus aureus biofilm inhibition by high voltage prick electrostatic field (HVPEF) and the mechanism investigation.

Int J Food Microbiol

February 2022

College of Food Science and Engineering, Jilin University, Changchun 130062, China. Electronic address:

The study was to investigate the inhibitory effect and mechanism of high voltage prick electrostatic field (HVPEF) on Staphylococcus aureus biofilms. Results showed that HVPEF effectively inactivated 24-h and 48-h established S. aureus biofilms, and the effect was verified on different food-contact materials.

View Article and Find Full Text PDF

In previous work, probe electrospray ionization/mass spectrometry (PESI/MS) and sheath-flow probe electrospray ionization/mass spectrometry (sfPESI/MS) were reported for the rapid and minimally invasive analysis of food. In this work, a modified version of sfPESI will be reported. The sample surface was pricked with an acupuncture needle inserted in the sfPESI probe that protruded from the terminus of the tip by 5 mm.

View Article and Find Full Text PDF

Rapid, direct, on-site and noninvasive food analysis is strongly needed for quality control of food. To satisfy this demand, the technique of dipping probe electrospray ionization/mass spectrometry (dPESI/MS) was developed. The sample surface was pricked with a fine acupuncture needle and a sample of ∼200 pL was captured at the needle tip.

View Article and Find Full Text PDF