Introduction: Validation of functional free-breathing MRI involves a comparison to more established or more direct measurements. This procedure is cost-intensive, as it requires access to patient cohorts, lengthy protocols, expenses for consumables, and binds working time. Therefore, the purpose of this study is to introduce a synthetic lung model (ASYLUM), which mimics dynamic MRI acquisition and includes predefined lung abnormalities for an alternative validation approach. The model is evaluated with different registration and quantification methods and compared with real data.

Methods: A combination of trigonometric functions, deformation fields, and signal combinations were used to create 20 synthetic image time series. Lung voxels were assigned either to normal or one of six abnormality classes. The images were registered with three registration algorithms. The registered images were further analyzed with three quantification methods: deformation-based or signal-based regional ventilation (JVent/RVent) analysis and perfusion amplitude (QA). The registration results were compared with predefined deformations. Quantification methods were evaluated regarding predefined amplitudes and with respect to sensitivity, specificity, and spatial overlap of defects. In addition, 36 patients with chronic obstructive pulmonary disease were included for verification of model interpretations using CT as the gold standard.

Results: One registration method showed considerably lower quality results (76% correlation vs. 92/97%,  ≤ 0.0001). Most ventilation defects were correctly detected with RVent and QA (e.g., one registration variant with sensitivity ≥78%, specificity ≥88). Contrary to this, JVent showed very low sensitivity for lower lung quadrants (0-16%) and also very low specificity (1-29%) for upper lung quadrants. Similar patterns of defect detection differences between RVent and JVent were also observable in patient data: Firstly, RVent was more aligned with CT than JVent for all quadrants ( ≤ 0.01) except for one registration variant in the lower left region. Secondly, stronger differences in overlap were observed for the upper quadrants, suggesting a defect bias in the JVent measurements in the upper lung regions.

Conclusion: The feasibility of a validation framework for free-breathing functional lung imaging using synthetic time series was demonstrated. Evaluating different ventilation measurements, important differences were detected in synthetic and real data, with signal-based regional ventilation assessment being a more reliable method in the investigated setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11409849PMC
http://dx.doi.org/10.3389/fmed.2024.1418052DOI Listing

Publication Analysis

Top Keywords

quantification methods
12
synthetic lung
8
lung model
8
model asylum
8
validation functional
8
lung
8
functional lung
8
lung imaging
8
ventilation measurements
8
time series
8

Similar Publications

Faricimab efficacy in type 1 macular neovascularization: AI-assisted quantification of pigment epithelium detachment (PED) volume reduction over 12 months in Naïve and switch eyes.

Int J Retina Vitreous

January 2025

Fondation Asile des Aveugles, Department of Ophthalmology, Jules-Gonin Eye Hospital, University of Lausanne, Avenue de France 54, Lausanne, 1001, Switzerland.

Background: This study evaluates the efficacy of intravitreal Faricimab in reducing pigment epithelium detachment (PED) and fluid volumes in both treatment-naïve eyes and eyes unresponsive to anti-VEGF mono-therapies, all diagnosed with type 1 macular neovascularization (T1 MNV) over a period of 12-month.

Methods: A retrospective, single-center cohort study was conducted at the Jules Gonin Eye Hospital, Lausanne, Switzerland. Clinical records of treatment-naïve and non-responder switch patients presenting T1 MNV secondary to neovascular age-related macular degeneration (nAMD) from September 2022 to March 2023 were reviewed.

View Article and Find Full Text PDF

Indirect determination of hemoglobin A2 reference intervals in Pakistani infants using data mining.

BMC Med Inform Decis Mak

January 2025

Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Stadium Road, Karachi, 74800, Pakistan.

Background: Reference intervals (RIs) are crucial for distinguishing healthy from sick individuals and vary across age groups. Hemoglobinopathies are common in Pakistan, making the quantification of hemoglobin variants essential for screening. Direct RIs are established by measuring values from a healthy reference population, whereas indirect RIs, use statistical analysis of routine lab data to estimate values, making it feasible in settings where direct data is unavailable.

View Article and Find Full Text PDF

Pembrolizumab plus Lenvatinib is regarded as a significant treatment option for advanced unresectable hepatocellular carcinoma (HCC). This study aims to meticulously monitor and identify adverse events (AEs) related to this combined therapy, enhance patient safety, and offer evidence-based recommendations for the appropriate use of these drugs. We gathered adverse drug reactions (ADRs)-related data from the FAERS database for HCC patients who received Pembrolizumab, both alone and in combination with Lenvatinib from the first quarter of 2014 to the fourth quarter of 2023.

View Article and Find Full Text PDF

Nowadays, synthetic cathinones (SCs) is the second more representative subclass of New Psychoactive Substances, accounting for 104 analogues in the illegal market. Since its first report in 2011, α-pyrrolidinovalerophenone (α-PVP) gained popularity among drug users, provoking an increased number of intoxications. Nonetheless, pharmacokinetics data is still limited in the literature.

View Article and Find Full Text PDF

Wireless power-up and readout from a label-free biosensor.

Biomed Microdevices

January 2025

Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.

Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!