Background: Mixed venous saturation (SvO2) is considered the gold standard to assess the adequacy of tissue oxygen delivery (DO2) in shock states. However, SvO2 monitoring is challenging as it requires an invasive catheter and frequent blood sampling. Non-invasive methods, including near-infrared spectroscopy, have demonstrated low sensitivity to tissue dysoxia.

Methods: We fabricated a new device that uses resonance Raman spectroscopy (RRS) to quantify oxyhemoglobin saturation (ShbO2) in the esophagus (eShbO2), tongue (tShbO2), and liver (hShbO2). In two rat models of hemorrhagic shock, we quantified (1) The correlation of RRS-measured ShbO2 to SvO2 during progressive hemorrhage (n=20) and (2) The value of these metrics to predict near-term mortality in fixed, severe hemorrhage (mean blood pressure =25 mm Hg; n=18).

Results: In model 1, eShbO2 (r=0.705, p<0.0001) and tShbO2 (r=0.724, p<0.0001) correlated well with SvO2 and with serum lactic acid (eShbO2-lactate r=0.708, p<0.0001; tShbO2-lactate r=0.830, p<0.0001). hShbO2 correlated poorly with both SvO2 and lactic acid. Using time-matched ShbO2-SvO2 pairs, the performance of ShbO2 to detect severe tissue hypoxia (SvO2<20%) was excellent (AUC 0.843 for eShbO2, 0.879 for tShbO2). In model 2, eShbO2 showed a maximized threshold of 40% with 83% of animals dying within 45 minutes of this cut-off, demonstrating accuracy as a monitoring device. This was similar for tShbO2, with a threshold of 50%, predicting death within 45 minutes in 76% of animals. ShbO2 showed superior sensitivity to invasive monitoring parameters, including MABP<30 mm Hg (sensitivity 59%), pulse pressure<15 mm Hg (sensitivity 50%), and heart rate>220 bpm (sensitivity 39%, p=0.004).

Conclusions: eShbO2 represents a new paradigm to assess the adequacy of DO2 to a tissue. It constitutes a promising monitoring method to evaluate tissue oxygen saturation in real time and non-invasively, correlating with SvO2 and time to death.

Level Of Evidence: Level III, therapeutic/care management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11409389PMC
http://dx.doi.org/10.1136/tsaco-2024-001480DOI Listing

Publication Analysis

Top Keywords

oxyhemoglobin saturation
8
hemorrhagic shock
8
esophageal oxyhemoglobin
4
saturation resuscitative
4
resuscitative metric
4
metric hemorrhagic
4
shock background
4
background mixed
4
mixed venous
4
venous saturation
4

Similar Publications

Sapropelic muds have been used for centuries to treat various illnesses, but their effects and mechanisms are still under research. In this study the effects of Techirghiol sapropelic mud on tissue oxygenation in elderly patients diagnosed with neuromuscular disorders were investigated using spatial and spectral information provided by hyperspectral imaging technique. A group of 38 elderly patients with neuromuscular disorders for which they received mud therapy was studied.

View Article and Find Full Text PDF

Transcranial direct current stimulation (tDCS) is often reported to have positive effects on brain hemodynamics as well as cognitive performance. Binaural beats (BBs) have also shown the potential to improve cognitive performance. However, we could not find any studies assessing prefrontal hemodynamics using a combination of these techniques or assessing the effects on hemodynamic response at different intensity levels of tDCS (two and three mA).

View Article and Find Full Text PDF

Significance: Reference cerebral near-infrared spectroscopy (NIRS) data on the pediatric population are scarce, and in most cases, only cerebral oxygen saturation ( ) measured by continuous wave spatially resolved spectroscopy NIRS is reported. Absolute data for baseline optical and hemodynamic parameters are missing.

Aim: We aimed at collecting baseline cerebral optical parameters [absorption coefficient, ; reduced scattering coefficient, ; differential pathlength factor (DPF)] and hemodynamic parameters [oxy-hemoglobin content ( ), deoxyhemoglobin content (HHb), total hemoglobin content (tHB), ] in a large cohort of pediatric patients.

View Article and Find Full Text PDF

Background: Pulse oximetry measures oxygen saturation non-invasively by using differential absorption of infrared signals which are dependent on the oxyhaemoglobin:deoxyhaemoglobin ratio. We tested the hypothesis that pulse oximetry error in measurements of blood oxygen saturations may be associated with blood haemoglobin levels.

Methods: The study design was an observational study of all adult patients admitted to a large teaching hospital with suspected or confirmed COVID-19 infection from February 2020 to December 2021 who had arterial blood gases (ABG) drawn.

View Article and Find Full Text PDF

Objective: To assess the role of blood gas analysis as an auxiliary tool for detecting and predicting the progression of COVID-19 in patients.

Research Methodology/design: A consecutive cohort study was conducted of 106 patients diagnosed with the novel coronavirus. Patients were divided into two groups based on age and the course of the disease (mild to moderate and severe).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!