A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accelerated Recovery of DC Blocking Using Repolarization. | LitMetric

Accelerated Recovery of DC Blocking Using Repolarization.

Int IEEE EMBS Conf Neural Eng

Case Western Reserve University 10900 Euclid Ave., Cleveland, Ohio 44106; MetroHealth Medical Center 2500 MetroHealth Dr Cleveland, OH 44109; and Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, Ohio, 44106.

Published: March 2019

Direct current (DC) can be applied to a nerve to generate a complete nerve block. However, using conventional platinum electrodes, reactions occur at the nerve interface causing damage to the nerve. The electrode can be separated from the nerve using a biocompatible, ionically conducting medium, which isolates the damaging reactions in a vessel away from the nerve. This electrode has previously been referred to as the Separated Interface Nerve Electrode (SINE). Recent experiments have shown that when a complete block is applied, for a prolonged period of time, there is a delay in the recovery of the response. For many applications it would be advantageous to have instantaneous recovery. To achieve this, the SINE electrode was used to provide a complete, instantaneous nerve block at the block threshold for 10 minutes and then the current was reversed for selected time periods to determine if instantaneous recovery could be achieved. Depending on the length of time of the repolarization, the amount of time for recovery can be reduced by as much as 50%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11407070PMC
http://dx.doi.org/10.1109/ner.2019.8716928DOI Listing

Publication Analysis

Top Keywords

nerve electrode
12
nerve
8
nerve block
8
instantaneous recovery
8
accelerated recovery
4
recovery blocking
4
blocking repolarization
4
repolarization direct
4
direct current
4
current applied
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!