Background: In a previous study we have shown that a cemented vitamin E-doped highly cross-linked polyethylene (VEPE) compared to a conventional polyethylene cup in total hip arthroplasty (THA) has a slightly higher proximal migration but significantly lower wear rates up to 2 years after surgery. In this follow-up study we investigated the same cohort at 6 years.
Methods: This was a double-blinded, non-inferiority, randomised controlled trial on patients with osteoarthritis, with a mean age of 66 years. Patients were randomly assigned to receive either the conventional polyethylene cup or the VEPE cup in a 1:1 ratio. The primary endpoint was proximal implant migration of the cup measured with radiostereometric analysis (RSA). Secondary endpoints included wear rate of the cup and patient-reported outcome measurements (PROM).
Results: At the 6-year follow-up, 25 patients (11 controls, 14 VEPE) were available for RSA measurements, and we found no statistically significant difference in proximal migration between the VEPE and control groups. The wear rate was significantly lower in the VEPE group compared to controls, 0.03 mm/year and 0.07 mm/year, respectively with a mean difference 0.04 mm, (95% CI, 0.02-0.06 mm). There were no cup revisions and no difference in PROM between the groups.
Conclusions: Based on our 6-year results, the VEPE group exhibited no statistical or clinically relevant difference compared to the control group, and the wear rate was significantly lower in the VEPE group. The use of a cemented vitamin E-doped highly cross-linked cup is a good option in total hip arthroplasty.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538750 | PMC |
http://dx.doi.org/10.1177/11207000241267971 | DOI Listing |
J Appl Oral Sci
November 2024
Universidade Estadual de Campinas - UNICAMP, Faculdade de Odontologia de Piracicaba, Piracicaba, SP, Brasil.
Objective: Periodontal dental ligament mesenchymal stem cells (PDLMSCs) play a major role in periodontal tissue regeneration by the neoformation of root cementum and alveolar bone. These cells are highly heterogeneous, and many present low potential to renovate the hard tissue damaged by periodontal disease. A previous study found that the low osteoblast/cementoblast (O/C) differentiation potential of PDLMSCs is related to high asporin (ASPN) expression, which was identified as a negative regulator of PDL cells differentiation and mineralization, suppressing BMP-2-induced O/C differentiation.
View Article and Find Full Text PDFJ Orthop Case Rep
November 2024
Department of Orthopaedic, Sri Madhusudan Sai Institute of Medical Sciences and Research, Chikkaballapur, Karnataka, India.
Introduction: The annual incidence of fractured neck of femur in the elderly continues to rise year after year. Longer lifespan also contributes to the increase in the incidence of fracture neck of femur. Contributing factors include genetic factors, reduced bone mineral density, physical inactivity, aging population, and environmental factors such as diet and vitamin D levels.
View Article and Find Full Text PDFHip Int
November 2024
Department of Clinical Sciences at Danderyd Hospital, Unit of Orthopaedics, Karolinska Institute, Stockholm, Sweden.
Background: In a previous study we have shown that a cemented vitamin E-doped highly cross-linked polyethylene (VEPE) compared to a conventional polyethylene cup in total hip arthroplasty (THA) has a slightly higher proximal migration but significantly lower wear rates up to 2 years after surgery. In this follow-up study we investigated the same cohort at 6 years.
Methods: This was a double-blinded, non-inferiority, randomised controlled trial on patients with osteoarthritis, with a mean age of 66 years.
Microsc Res Tech
January 2025
Department of Pediatric Dentistry Orthodontic Sciences, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia.
To assess micro-tensile bond strength (μTBS), degree of conversion (DC), microleakage (ML) antibacterial efficacy, and adhesive remnant index (ARI) of orthodontic brackets to enamel with different concentrations of photoactivated riboflavin-doped hydroxyapatite (HA) nanospheres (NS) (0%,1%,5% and 10%) and 0.5 wt% RF alone in orthodontic adhesive. Samples were included on the predefined inclusion criteria and positioned up to the cementoenamel junction (CEJ).
View Article and Find Full Text PDFPurpose: The aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.
Methods: Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!