A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transvenous closure of patent ductus arteriosus with Nit-Occlud® PDA occlusion system in 13 dogs weighing less than 3 kg. | LitMetric

Introduction: Successful closure of patent ductus arteriosus (PDA) can be obtained with surgical ligation or with occlusion via minimally invasive per-catheter techniques. This study was performed to assess feasibility and effectiveness of transjugular PDA occlusion in dogs weighing < 3 kg with a device called Nit-Occlud® PDA.

Animals: Thirteen client-owned dogs.

Materials And Methods: This was a retrospective study. Clinical records of dogs that underwent PDA occlusion with a Nit-Occlud® PDA were reviewed. Data collection included patients' signalment, clinical findings, pre- and post-procedure echocardiographic measurements, device size, procedure time and clinical outcome.

Results: The median age of these patients was six months (2.5-38.0 months), with a mean body weight of 2.44 ± 0.43 kg. The mean minimal ductal diameter (MDD) was 1.82 ± 0.43 mm, while the mean ampulla diameter (AD) was 5.51 ± 1.89 mm. Duct closure was successful in 12 cases. Minimal or no residual shunt was observed on echocardiography prior to device release. In one dog, the device was not released owing to unsatisfactory occlusion, prompting an alternative occlusion method. Follow-up echocardiographic examinations showed complete ductal closure and reversed cardiac remodelling in all cases where the device was successfully released.

Discussion: The Nit-Occlud® is deployed through a delivery system with an outer diameter of 4 Fr or 5 Fr, which makes this solution particularly attractive in patients where vascular access is challenging or unfeasible due to the small size of their vessels.

Conclusions: The Nit-Occlud® PDA appears a feasible and effective occlusion system in small patients weighing <3 kg.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvc.2024.08.005DOI Listing

Publication Analysis

Top Keywords

nit-occlud® pda
12
pda occlusion
12
closure patent
8
patent ductus
8
ductus arteriosus
8
occlusion system
8
dogs weighing
8
occlusion
7
pda
6
nit-occlud®
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!