Objective: Although a large body of evidence has reported on surgical approaches for the treatment of unstable intertrochanteric femoral fractures, studies that comprehensively evaluate treatment outcomes are limited. The purpose of this study was to compare the effectiveness of extramedullary fixation (i.e., dynamic hip screw [DHS]), intramedullary fixation (i.e., the proximal femoral nailing [PFN]), and hemiarthroplasty (HA) for the treatment of unstable intertrochanteric femoral fractures using network meta-analysis.

Methods: This study meets the preferred reporting items for systematic reviews and meta-analyses criteria. The Patient, Intervention, Comparison and Outcome search protocol framework was used to search the Google Scholar, PubMed, Embase, and Cochrane Library databases were searched from inception until June 2023.

Results: A total of 15 randomized controlled trials, including 1282 patients were analyzed. The Harris hip score (HHS) after DHS fixation was the lowest compared with that of PFN fixation and HA. DHS fixation had a significantly longer operation time than that of PFN fixation. Compared with HA, a lower incidence of superficial wound infection was observed with PFN and DHS fixations. PFN was significantly more likely to be implant cut out compared with HA. Compared with DHS, PFN and HA showed a lower incidence of fracture healing malunion.

Conclusion: HA and PFN have good efficacy in improving the HHS and preventing joint deformities. However, HA showed a higher incidence of superficial infection than that observed with PFN, whereas a higher risk of screw cutout is observed with PFN than with HA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11404887PMC
http://dx.doi.org/10.1097/MD.0000000000039676DOI Listing

Publication Analysis

Top Keywords

unstable intertrochanteric
12
observed pfn
12
treatment unstable
8
intertrochanteric femoral
8
femoral fractures
8
dhs fixation
8
pfn
8
pfn fixation
8
lower incidence
8
incidence superficial
8

Similar Publications

The aim was to study the independent risk factors of internal fixation failure in proximal femoral anti-rotation intramedullary nailing for intertrochanteric femur fracture, and to build a nomogram prediction model accordingly. Clinical data of patients with intertrochanteric femoral rotor fractures admitted to the First People's Hospital of Longquanyi District from January 2018 to January 2023 were retrospectively collected. The occurrence of spiral blade cut out, internal fixation breakage, peri-internal fixation fracture, hip internal rotation deformity, and fracture nonunion within 1 year after surgery were included in the internal fixation failure group, and the rest were included in the internal fixation success group.

View Article and Find Full Text PDF

Predictive Factors for Cut-Out Risks of Unstable Trochanteric Fractures.

Cureus

November 2024

Diabetes and Endocrinology, National Institute of Diabetes, Nutrition and Metabolic Diseases-Prof. N. Paulescu, Bucharest, ROU.

Fractures of the trochanteric mass represent a significant proportion of hip fractures. These fractures often occur in the elderly due to compromised bone quality, leading to a high predisposition for instability at the fracture site. The study was conducted through a retrospective analysis of 1,259 hospitalizations in the Department of Orthopedics and Traumatology of the Bucharest University Emergency Hospital between 2022 and 2023, including patients with various types of trochanteric mass fractures: basicervical, per trochanteric, intertrochanteric, subtrochanteric, and trochanter-diaphyseal fractures.

View Article and Find Full Text PDF

Effectiveness of the Dorr index in predicting implant failure before proximal femoral nail application.

Jt Dis Relat Surg

January 2025

Dr. Abdurrahman Yurtaslan Ankara Onkoloji Eğitim ve Araştırma Hastanesi, Ortopedi ve Travmatoloji Kliniği, 06200 Yenimahalle, Ankara, Türkiye.

Objectives: This study aimed to investigate the importance of the Dorr index in the preoperative evaluation of implant failure in patients who underwent proximal femoral nail (PFN).

Patients And Methods: This retrospective study examined 312 patients who underwent PFN for intertrochanteric fractures between January 2016 and January 2020. Patients with unstable fractures according to the AO/OTA (AO Foundation/Orthopaedic Trauma Association) classification, those over 65 years of age, with at least one year of regular follow-up, a tip-apex distance <25 mm, and a caput-collum-diaphyseal angle between 125° and 135°, were included.

View Article and Find Full Text PDF

A novel load-sensing sliding hip screw to aid in the assessment of intertrochanteric fracture healing.

J Biomech

January 2025

Clemson University, Department of Bioengineering, 301 Rhodes Building, Clemson, SC 29634, United States; Aravis BioTech LLC, 17 Claret Dr., Greenville SC 29609, United States. Electronic address:

Bone healing after sliding hip screw internal fixation of intertrochanteric hip fractures is difficult to monitor with radiography. In this study, we describe and evaluate a device to non-invasively determine the loading on the screw implant as a possible qualitative indicator of bone healing. A novel load-sensing sliding hip screw (LS-SHS) was fabricated containing a radio-dense tungsten indicator rod that moves and can be measured within the screw cannulation when the screw bends under load via plain radiography.

View Article and Find Full Text PDF

Introduction: fixation of unstable intertrochanteric fractures presents a significant challenge, especially in the context of osteoporosis. Intramedullary implants have been established as superior to plate constructs. Our aim is to compare the complications and clinical outcomes of the Proximal Femur Nail (PFN) and Proximal Femur Nail Antirotation-2 (PFNA2) in managing unstable intertrochanteric fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!