Background: The trabeculae-oriented pattern (TOP) cup was designed to minimize acetabular periprosthetic bone loss. In our previous prospective study comprising 30 patients with a two-year follow-up we found a substantial decrease in periprosthetic bone mineral density (pBMD) in the proximal and medial regions of the TOP cup. The present study aims to investigate pBMD changes in the mid-term and how this affects implant survival.
Methods: We followed the previous cohort and estimated implant survival by Kaplan-Meier analysis, evaluated pBMD with dual-energy X-ray absorptiometry (DXA) and clinical outcome using the Harris Hip Score (HHS).
Results: Mean follow-up was 8.6 (range 7.8-9.1) years. The eight-year implant survival rate for cup revision for all reasons was 83% (95% confidence interval {CI}: 70-97) and 86% (CI: 74-99) when cup revision due to aseptic loosening was the endpoint. Mean HHS at eight years was 95 (range 77-100). A further 12% (CI: 5-17) loss in pBMD was detected in the proximal Digas zone 1 and 12% (CI: 7-17) loss in Digas zone 2 also between two and eight years after surgery. pBMD continued to decrease up to 30% (CI: 24-36) in Digas zones 1, 2 and 3 compared to pBMD immediately postoperatively.
Conclusions: The TOP cup shows inferior mid-term survival rates compared to other uncemented cups, as well as a continuous decrease in pBMD. Periprosthetic bone loss cannot be prevented by this uncemented cup.
Clinical Trial Number: Not applicable.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11403771 | PMC |
http://dx.doi.org/10.1186/s12891-024-07865-5 | DOI Listing |
J Bone Joint Surg Am
January 2025
Leeds Institute of Health Sciences, School of Medicine, University of Leeds, Leeds, West Yorkshire, England.
Background: In this study, we estimated the risk of surgically treated postoperative periprosthetic femoral fractures (POPFFs) associated with femoral implants frequently used for total hip arthroplasty (THA).
Methods: In this cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020, POPFFs were identified from prospectively collected revision records and national hospital records. POPFF incidence rates, adjusting for potential confounders, were estimated for common stems.
J Orthop Surg Res
January 2025
Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna, Bologna, Italy.
Background: Transfemoral osseointegrated prostheses, like other uncemented prostheses experience the risk of aseptic loosening and post-operative periprosthetic fractures, with an incidence between 3% and 30%. To date, however, osseointegrated off-the-shelf prostheses are manufactured in a limited number of sizes, and some patients do not meet the strict eligibility criteria of commercial devices. A customized osseointegrated stem was developed and a pre-clinical in vitro investigation of the stem was performed, to evaluate its biomechanical performance.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopaedic Surgery, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea.
Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Orthopedic Surgery, Ajou University School of Medicine, Suwon 16499, Republic of Korea.
Valgus-impacted femoral neck fractures (OTA 31B1.1 and 31B1.2) are considered stable fractures with favorable outcomes compared to displaced fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!