This study aimed to investigate the biocompatibility and osseointegration of novel titanium (Ti) implants with a perforated part with high surface roughness (Ra >4 μm) and a smooth solid part (test group), as compared to smooth solid Ti implants (control group; Ra < 0.8 μm). Test and control implants were implanted in rabbit femurs. After 4 and 15 weeks, host tissue reaction and quality of tissue formed were evaluated with histopathology, while micro-CT scans were used to quantitatively assess bone-implant contact (BIC), surrounding bone formation, and bone ingrowth. After 4 and 15 weeks, minimal host reaction was found in the test group. Histopathological analysis showed new bone formation around the implants in both the test and control groups after 4 weeks. Furthermore, additional bone growth was often observed within the holes of the test implants. After 15 weeks, the test implants showed high bone ingrowth and the presence of mature bone in direct contact with the implant surface, whereas, bone ingrowth was poorer for the control group with 30% of the control implants, showing larger gaps at the bone-implant interface. Quantitative micro-CT analysis revealed comparable BIC and bone formation in both groups at 4 weeks, but higher BIC and more bone formation in the test group than in the control group after 15 weeks. No significant differences were observed in any of the analyses. In conclusion, partially perforated, high-roughness Ti implants showed excellent osseointegration and minimal host reaction, indicating their potential for orthopedic applications in bone repair and regeneration.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.25974DOI Listing

Publication Analysis

Top Keywords

biocompatibility osseointegration
8
smooth solid
8
evaluation biocompatibility
4
osseointegration multi-component
4
multi-component tial6v4
4
tial6v4 titanium
4
titanium alloy
4
alloy implants
4
implants study
4
study aimed
4

Similar Publications

Effective Bone Tissue Fabrication Using 3D-Printed Citrate-Based Nanocomposite Scaffolds Laden with BMP9-Stimulated Human Urine Stem Cells.

ACS Appl Mater Interfaces

December 2024

Molecular Oncology Laboratory, Department of Orthopedic Surgery and Rehabilitation Medicine, The University of Chicago Medical Center; Chicago, Illinois 60637, United States.

Effective repair of large bone defects through bone tissue engineering (BTE) remains an unmet clinical challenge. Successful BTE requires optimal and synergistic interactions among biocompatible scaffolds, osteogenic factors, and osteoprogenitors to form a highly vascularized microenvironment for bone regeneration and osseointegration. We sought to develop a highly effective BTE system by using 3D printed citrate-based mPOC/hydroxyapatite (HA) composites laden with BMP9-stimulated human urine stem cells (USCs).

View Article and Find Full Text PDF

Objective: Aseptic loosening (AL) is a common mechanical complication following reconstruction of the distal femoral cemented prosthesis (DFCP), often resulting in severe bone loss, which complicates prosthesis revision. 3D-printed personalized implants represent an emerging solution for the reconstruction of complex bone defects. This study aimed to investigate the early therapeutic effects of using a 3D-printed, customized, uncemented stem prosthesis for revising aseptic AL in DFCP.

View Article and Find Full Text PDF

Background: Ceramic endosseous implant coatings have gained esteem due to their favorable osteoinductive and osteoconductive properties. However, such a layer may be prone to failure under in vivo conditions, which necessitates its modification.

Objectives: The aim of the present study was to modify an electrodeposited hydroxyapatite (HA) coating on titanium (Ti) with ultrashort-pulsed lasers for the incorporation of the ceramic into the sample surface and the texturing of the metal surface.

View Article and Find Full Text PDF

Osseointegration of Implants Through Ti Biofunctionalization with Biomass from UTEX 1230 and sp. PCC 7002.

Int J Mol Sci

December 2024

Biomedical Engineering Department, Universidad Simón Bolívar, Barranquilla 080002, Colombia.

The inadequate osseointegration of titanium implants remains a significant challenge in orthopedics, limiting the long-term efficacy of prostheses and medical devices. It has been determined that biological aging of the titanium surface compromises the implant-bone tissue interaction due to increased hydrophobicity and accumulation of organic molecules. To address this issue, an innovative strategy has been proposed: the biofunctionalization of Ti6Al4V surfaces utilizing biomass derived from UTEX 1230 and sp.

View Article and Find Full Text PDF

3D-printed microporous titanium scaffolds enjoy good biointegration with the residuum's soft and bone tissues, and they promote excellent biomechanical properties in attached prostheses. Implant-associated infection, however, remains a major clinical challenge. Silver-based implant coatings can potentially reduce bacterial growth and inhibit biofilm formation, thereby reducing the risk of periprosthetic infections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!