A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating Joint Angle Data for Clinical Assessment Using Multidimensional Inverse Kinematics with Average Segment Morphometry. | LitMetric

Evaluating Joint Angle Data for Clinical Assessment Using Multidimensional Inverse Kinematics with Average Segment Morphometry.

bioRxiv

Department of Human Performance, Division of Physical Therapy, School of Medicine, West Virginia University, Department of Neuroscience, School of Medicine, West Virginia University, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, USA.

Published: September 2024

Movement analysis is a critical tool in understanding and addressing various disabilities associated with movement deficits. By analyzing movement patterns, healthcare professionals can identify the root causes of these alterations, which is essential for preventing, diagnosing, and rehabilitating a broad spectrum of medical conditions, disabilities, and injuries. With the advent of affordable motion capture technologies, quantitative data on patient movement is more accessible to clinicians, enhancing the quality of care. Nonetheless, it is crucial that these technologies undergo rigorous validation to ensure their accuracy in collecting and monitoring patient movements, particularly for remote healthcare services where direct patient observation is not possible. In this study, motion capture technology was used to track upper extremity movements during a reaching task presented in virtual reality. Kinematic data was then calculated for each participant using a scaled dynamic inertial model. The goal was to evaluate the accuracy of joint angle calculations using inverse kinematics from motion capture relative to the typical movement redundancy. Shoulder, elbow, radioulnar, and wrist joint angles were calculated with models scaled using either direct measurements of each individual's arm segment lengths or those lengths were calculated from individual height using published average proportions. The errors in joint angle trajectories calculated using the two methods of model scaling were compared to the inter-trial variability of those trajectories. The variance of this error was primarily within the normal range of variability between repetitions of the same movements. This suggests that arm joint angles can be inferred with good enough accuracy from motion capture data and individual height to be useful for the clinical assessment of motor deficits.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11398373PMC
http://dx.doi.org/10.1101/2024.09.03.611088DOI Listing

Publication Analysis

Top Keywords

motion capture
16
joint angle
12
clinical assessment
8
inverse kinematics
8
joint angles
8
individual height
8
movement
5
evaluating joint
4
data
4
angle data
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!