A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rigicon ContiClassic and ContiReflex artificial urinary sphincter devices. | LitMetric

Rigicon ContiClassic and ContiReflex artificial urinary sphincter devices.

Transl Androl Urol

Department of Urology, Princess Alexandra Hospital, University of Queensland, Brisbane, QLD, Australia.

Published: August 2024

The modern AMS 800 artificial urinary sphincter (AUS) is often considered the standard of care for the treatment of moderate to severe stress urinary incontinence in male patients. Nonetheless, the AMS 800 device has several inherent limitations, and these factors can potentially impact its clinical utility and impede excellent clinical outcomes. The new Rigicon AUS devices such as ContiClassic and ContiReflex urinary sphincters are designed to overcome some of the existing issues pertaining to the AMS 800 device. The ContiClassic device is similar in terms of device design to the AMS 800 apart from the inclusion of a hydrophilic coating, has a greater range of cuff sizes with 0.25-cm diameter increments, and an Easy Clink Connectors which negates the need for an assembly tool. In contrast, The ContiReflex device differs from the ContiClassic model in that it features an extra stress relief balloon (SRB) to provide a safeguard on the urethral occlusive mechanism against any sudden increase in intra-abdominal pressure, and a larger pump system that is responsible to cycle fluid between the higher pressure two-balloon system and the sphincteric cuff. The following brief report evaluates the current device design and technology of the Rigicon ContiClassic and ContiReflex AUS devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399054PMC
http://dx.doi.org/10.21037/tau-23-464DOI Listing

Publication Analysis

Top Keywords

ams 800
16
conticlassic contireflex
12
rigicon conticlassic
8
artificial urinary
8
urinary sphincter
8
800 device
8
aus devices
8
device design
8
device
6
contireflex
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!