Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study explores the dosimetric benefits of cone-beam computed tomography (CBCT)-based online adaptive radiation therapy (oART) for a non-small-cell lung cancer (NSCLC) patient exhibiting significant tumor shrinkage during ChemoRT. The patient was prescribed 60 Gray (Gy) in 30 fractions and was initially treated with conventional RT. After the delivery of the first four treatment fractions, the patient's treatment course was converted to oART due to tumor shrinkage seen on CBCT. Current oART dose calculations use a synthetic CT (sCT) image derived from deformable image registration (DIR) of the planning CT to the daily CBCT, and, as the tumor regressed, the discrepancy between the CBCT and the sCT increased, leading to a re-simulation after the delivery of the ninth fraction. In this case report, we first investigated dosimetric differences leveraged by converting this patient from conventional RT to oART. With oART using sCT, the patient's target coverage remained consistent with the reference plan while simultaneously changing lung V20 by 7.8 ± 1.4% and heart mean by 3.4 ± 1.5 Gy. Then, using this new simulation CT and comparing it with iterative CBCT (iCBCT) images acquired with the new HyperSight™ (HS) (Varian Medical Systems, Inc., Palo Alto, CA, USA) imaging system on the Ethos, we investigated the impact of direct dose calculation on HS-iCBCT as compared to sCT. The HS-iCBCT generated a dose distribution similar to the CT reference, achieving a 96.01% gamma passing rate using Task Group-218 (TG-218) criteria. Results indicate that HS-iCBCT has the potential to better reflect daily anatomical changes, resulting in improved dosimetric accuracy. This study highlights the advantages of oART in the presence of tumor response to therapy and underscores HS-iCBCT's potential to provide CT-level dose calculation accuracy in oART for NSCLC patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11401639 | PMC |
http://dx.doi.org/10.7759/cureus.66943 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!