Background: Tentorium resection and detachment from the oculomotor nerve are sometimes required for surgical clipping of unruptured posterior communicating artery (PCoA) aneurysms. Using T2-weighted 3D images, we aimed to identify the preoperative radiological features required to determine the necessity of these additional procedures.

Methods: We reviewed 30 patients with unruptured PCoA aneurysms who underwent surgical clipping and preoperative simulation using T2-weighted 3D images for measurement of the distance between the tentorium and aneurysm. Aneurysms were classified into superior type (superior to the tentorium) and inferior type (inferior to the tentorium).

Results: Seven patients (23%) underwent tentorium resection; all had the inferior type (superior vs. inferior, 0% vs. 33%, p = 0.071). In the 21 patients with the inferior type, the distance from the tentorium to the aneurysmal neck was 2.2 ± 1.1 mm and 0.0 ± 0.5 mm without and with tentorium resection (p < 0.01), respectively. An optimal cutoff value of ≤ +0.84 mm was identified for tentorium resection (area under the curve (AUC) = 0.96). Furthermore, 17 patients (57%) showed tight aneurysm attachment to the oculomotor nerve; all had the inferior type (0% vs. 81%, p < 0.01). The distance from the aneurysm tip to the tentorium was 1.1 ± 1.2 mm and -1.7 ± 1.4 mm without and with attachment (p < 0.01). The optimal cutoff value was ≤ +0.45 mm (AUC = 0.92).

Conclusions: Measurement of the distance between the tentorium and aneurysmal neck or tip with T2-weighted 3D images is effective for preoperative simulation for surgical clipping of PCoA aneurysms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11395932PMC
http://dx.doi.org/10.7759/cureus.66851DOI Listing

Publication Analysis

Top Keywords

surgical clipping
16
t2-weighted images
16
tentorium resection
16
inferior type
16
preoperative simulation
12
pcoa aneurysms
12
distance tentorium
12
tentorium
9
posterior communicating
8
communicating artery
8

Similar Publications

Study on the Abrasive Blasting Mechanism of Solder Welded 304V Wire in Vascular Intervention.

Micromachines (Basel)

November 2024

Department of Vascular Surgery, General Surgery Clinical Center, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, 100 Haining Road, Shanghai 200080, China.

The solder burrs on the 304V wire surface can easily scratch the vascular tissue during interventional treatment, resulting in complications such as medial tears, bleeding, dissection, and rupture. Abrasive blasting is often used to remove solder burr and obtain a smooth surface for the interventional device. This study conducted an abrasive blasting experiment to explore the effects of process parameters (air pressure, lift-off height, abrasive volume, and abrasive type) on processing time, surface roughness, and mechanical properties to reveal the material removal mechanism.

View Article and Find Full Text PDF

The nanosecond pulsed fibre laser (NsPFL) treatment is extensively employed to distinguish hospital surgical instruments (micro-surgical forceps, surgical blades, orthopaedic drills, and high-precision laparoscopic tools), which are generally composed of stainless steel. Nevertheless, if the laser parameters are not properly optimised, this process may unintentionally provoke corrosion. Maintaining the structural integrity of these materials is essential for ensuring patient safety and minimising long-term costs.

View Article and Find Full Text PDF

: Third molar (wisdom tooth) extraction is one of the most common surgical procedures in oral and maxillofacial surgery. Traditional rotary instruments and burs have long been the standard tools for this procedure. However, recent advancements in surgical techniques, such as piezoelectric surgery, have gained popularity due to their purported advantages in terms of precision, safety, and postoperative outcomes.

View Article and Find Full Text PDF

Hysteroscopy is a key gynecological procedure for diagnosing and treating endometrial conditions. While hysteroscopy is often performed in office settings without sedation, patients frequently report significant pain during the procedure. This study aims to evaluate the efficacy of paracervical anesthesia with mepivacaine compared to placebo in managing pain during office hysteroscopy.

View Article and Find Full Text PDF

: Postoperative cerebrospinal fluid (CSF) fistulas remain a significant concern in spinal neurosurgery, particularly following dural closure. The incidence of dural tears during spinal surgery is estimated between 1.6% and 10%.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!