Catheter-based cardiac ablation is a minimally invasive procedure for treating atrial fibrillation (AF). Electrophysiologists perform the procedure under image guidance during which the contact force between the heart tissue and the catheter tip determines the quality of lesions created. This paper describes a novel multi-modal contact force estimator based on Convolutional Neural Networks (CNNs) and Recurrent Neural Networks (RNNs). The estimator takes the shape and optical flow of the deflectable distal section as two modalities since frames and motion between frames complement each other to capture the long context in the video frames of the catheter. The angle between the tissue and the catheter tip is considered a complement of the extracted shape. The data acquisition platform measures the two-degrees-of-freedom contact force and video data as the catheter motion is constrained in the imaging plane. The images are captured via a camera that simulates single-view fluoroscopy for experimental purposes. In this sensor-free procedure, the features of the images and optical flow modalities are extracted through transfer learning. Long Short-Term Memory Networks (LSTMs) with a memory fusion network (MFN) are implemented to consider time dependency and hysteresis due to friction. The architecture integrates spatial and temporal networks. Late fusion with the concatenation of LSTMs, transformer decoders, and Gated Recurrent Units (GRUs) are implemented to verify the feasibility of the proposed network-based approach and its superiority over single-modality networks. The resulting mean absolute error, which accounted for only 2.84% of the total magnitude, was obtained by collecting data under more realistic circumstances in contrast to previous research studies. The decrease in error is considerably better than that achieved by individual modalities and late fusion with concatenation. These results emphasize the practicality and relevance of utilizing a multimodal network in real-world scenarios.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11392016 | PMC |
http://dx.doi.org/10.1109/tmrb.2024.3407590 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Applied Mathematics Laboratory, Courant Institute of Mathematical Sciences, Department of Mathematics, New York University, New York, NY 10012.
Mechanical systems with moving points of contact-including rolling, sliding, and impacts-are common in engineering applications and everyday experiences. The challenges in analyzing such systems are compounded when an object dynamically explores the complex surface shape of a moving structure, as arises in familiar but poorly understood contexts such as hula hooping. We study this activity as a unique form of mechanical levitation against gravity and identify the conditions required for the stable suspension of an object rolling around a gyrating body.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
Objective: Finite element analysis (FEA) of the biomechanical properties of the modified extraoral distractor device used in the mandibular distraction of craniofacial microsomia patients.
Materials And Methods: Finite element analysis (FEA) models of 5 patients under 2 working conditions, the instance when the distractor is activated and when the distractor participates in mastication, were included in the current study. To conduct the FEA, load boundary conditions (35.
J Contemp Dent Pract
September 2024
Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.
Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.
J Biomech Eng
January 2025
Human-Centric Design Research Lab, Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
This study presents a comprehensive finite element model for the human wrist, constructed from a CT scan of a 68-year-old male (type I wrist). This model intricately captures the bone and soft tissue geometries to study the biomechanics of wrist axial loading through tendon-driven simulations and grasping biomechanics using metacarpal loads. Validation is carried out by assessing the radial and ulnar axial loading distribution, radiocarpal articulation contact patterns, and other standard finite element metrics.
View Article and Find Full Text PDFSoft Matter
January 2025
Delft University of Technology, Process & Energy Laboratory, Leeghwaterstraat 39, 2628 CB Delft, The Netherlands.
The jamming transition of soft particles characterized by narrow size distributions has been well studied by physicists. However, polydispersed systems are more relevant to engineering, and the influence of polydispersity on jamming phenomena is still unexplored. Here, we numerically investigate jamming transitions of polydispersed soft particles in two dimensions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!