The service life of the lithium-oxygen (Li-O) battery is an essential factor in measuring the performance of the battery, and it is also imperative to clarify the reason for battery termination. In this work, the positive electrode of a nonaqueous Li-O battery was selected after cutoff under different discharge conditions, and the digital reconstruction model of the positive electrode was carried out by X-CT technology. The reconstructed positive electrode's structural characteristics, material transport characteristics, and electrical conductivity were analyzed. It is found that the positive electrode has an apparent expansion phenomenon after constant capacity cyclic charge and discharge, but this situation is not evident after deep discharge. After the constant capacity test is cut off, the product distribution range in the positive electrode is more comprehensive and the material transport efficiency is higher. However, after deep discharge, the product distribution in the positive electrode is more concentrated and the material transport efficiency is lower. There are apparent differences in the termination mechanism between constant capacity cycle discharge and deep discharge. This paper provides a compelling theoretical basis for revealing the discharge termination mechanism of nonaqueous Li-O batteries.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c10285DOI Listing

Publication Analysis

Top Keywords

positive electrode
20
termination mechanism
12
nonaqueous li-o
12
li-o battery
12
material transport
12
constant capacity
12
deep discharge
12
discharge termination
8
mechanism nonaqueous
8
digital reconstruction
8

Similar Publications

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

This study aims to evaluate factors influencing revision cochlear implant surgeries, including patient demographics, surgical techniques, and radiological findings. The main aim was to identify factors influencing surgical success to inform clinical treatment and enhance patient outcomes. This cross-sectional study included adult patients over the age of 18 who underwent revision cochlear implant surgery due to implant-related complications.

View Article and Find Full Text PDF

In this study, the potential to modify the phase structure and morphology of manganese dioxide synthesized via the hydrothermal route was explored. A series of samples were prepared at different synthesis temperatures (100, 120, 140, and 160 °C) using KMnO and MnSO·HO as precursors. The phase composition and morphology of the materials were analyzed using various physicochemical methods.

View Article and Find Full Text PDF

Rationale: Acute kidney injury (AKI) is a clinical syndrome associated with a multitude of conditions. Although renal replacement therapy (RRT) remains the cornerstone of treatment for advanced AKI, its implementation can potentially pose risks and may not be readily accessible across all healthcare settings and regions. Elevated lactate levels are implicated in sepsis-induced AKI; however, it remains unclear whether increased lactate directly induces AKI or elucidates the underlying mechanisms.

View Article and Find Full Text PDF

Background: Episiotomy is a surgical intervention performed during the second stage of labor to facilitate the baby's exit through the birth canal. There are different reasons that lead episiotomy; however, it is recommended performed occasionally and not systematically, since it may produce negative effects such as pain. Different therapies have been described to reduce this pain, including transcutaneous electrical nerve stimulation (TENS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!