Various industries produce a myriad of synthetic molecules used to satisfy our needs, but all these molecules are likely to reach aquatic environments. The number of organic contaminants found in rivers and lakes continues to rise, and part of this contamination gets transferred into sediments. Analytical methods to detect problematic substances in the environment often use mass spectrometry coupled with chromatography. Here we reviewed a set of 163 articles and compiled the relevant information into a comprehensive database for analysing organic contaminants in continental sediments including suspended particulate matter and surface and bottom sediments in lakes, rivers and estuaries. We found 1204 compounds detected at least once in sediments, and classified them into 11 categories, i.e. hydrocarbons, flame retardants, polychlorinated biphenyls (PCB), plasticizers, per- and poly-fluoroalkyl substances (PFAS), organochlorines (OCP) and other pesticides, pharmaceuticals, hormones, personal care products (PCP), and other contaminants. Concentrations of these compounds varied from a few ng to several mg/kg of dry sediment. Even hydrophilic compounds were detected in high concentrations. Well-known hydrophobic and persistent contaminants tend to be analysed with mass spectrometry coupled to gas chromatography (GC-MS) whereas contaminants of emerging concern (CEC) are usually analysed with liquid chromatography- mass spectrometry (LC-MS). Suspect screening and non-target analysis (NTA), which use high-resolution mass spectrometry, are still scarcely used on sediment but hold promise for gaining deeper knowledge of organic contamination in aquatic environments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chemosphere.2024.143275 | DOI Listing |
Anaesthesia
January 2025
Department of Anaesthesia and Perioperative Medicine, The Royal Brisbane and Women's Hospital, Brisbane, Australia.
Introduction: Evidence to support intra-operative lidocaine infusion regimens in patients with obesity is lacking, risking underdosing or toxicity. We aimed to measure the plasma concentrations of lidocaine and its active metabolites to develop a pharmacokinetic model and optimised dosing regimen in patients with obesity.
Methods: A standardised weight-based intravenous lidocaine regimen was administered to patients with a BMI ≥ 30 kg.
J Virol
December 2024
Key Laboratory of Animal Disease Diagnostics and Immunology, Ministry of Agriculture, MOE International Joint Collaborative Research Laboratory for Animal Health & Food Safety, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing, Jiangsu, China.
Porcine circovirus type 2 (PCV2) is the primary causative agent of porcine circovirus-associated disease, clinically resulting in immunosuppression and co-infections with other pathogens in infected pigs. The mechanism of PCV2 infection remains unclear. In this study, we firstly found that the tetraspanin CD81 in PK-15 cells interacts with PCV2 Cap protein by using virus overlay protein-binding assay combined with mass spectrometry.
View Article and Find Full Text PDFAppl Environ Microbiol
December 2024
School of Microbiology, University College Cork, Cork, County Cork, Ireland.
Unlabelled: APC 4099, isolated from bees' gut, has been identified as a promising candidate for food biopreservation. Antimicrobial activity screening revealed a broad-spectrum inhibition potential, ranging from gram-positive pathogenic bacteria to fungi responsible for food spoilage. Genomic analysis identified biosynthetic gene clusters coding for several antimicrobial peptides and secondary metabolites.
View Article and Find Full Text PDFVet Q
December 2025
Faculty of Veterinary Medicine, Department of Small Animals, Ghent University, Merelbeke, Belgium.
Chronic Kidney Disease (CKD) is one of the most common conditions affecting felines, yet the metabolic alterations underlying its pathophysiology remain poorly understood, hindering progress in identifying biomarkers and therapeutic targets. This study aimed to provide a comprehensive view of metabolic changes in feline CKD across conserved biochemical pathways and evaluate their progression throughout the disease continuum. Using a multi-biomatrix high-throughput metabolomics approach, serum and urine samples from CKD-affected cats ( = 94) and healthy controls ( = 84) were analyzed with ultra-high-performance liquid chromatography-high-resolution mass spectrometry.
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
70777 TUBITAK National Metrology Institute (TUBITAK UME), Kocaeli, Türkiye.
Objectives: An analytical protocol based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), which includes a peptide-based calibration strategy, was developed and validated for the determination of cardiac troponin I (cTnI) levels in clinical samples. Additionally, the developed method was compared with a protein-based calibration strategy, using cTnI serving as a model for low-abundant proteins. The aim is to evaluate new approaches for protein quantification in complex matrices, supporting the metrology community in implementing new methods and developing fit-for-purpose SI- traceable peptide or protein primary calibrators.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!