Body temperature is one of the most important physiological parameters of a human being used to assess his basic vital functions. In medical practice, various types of measuring instruments are used to measure temperature, such as liquid thermometers, electronic thermometers, non-contact ear thermometers, and non-contact forehead thermometers. Such body temperature measurement techniques require the connection of appropriate sensors to a person, and non-contact thermometers operate over short distances and force a specific position of the person during the measurement. As a result, using the above methods, it is practically impossible to perform body temperature measurements of a moving human being. A thermal imaging camera can be used effectively for the purpose of the temperature measurement of moving objects, but the remote measurement of a human body temperature using a thermal imaging camera is affected by many factors that are difficult to control. Accurate remote measurement of human body temperature requires a measurement system that implements a specialized temperature determination algorithm. This article presents a model of a measurement system that facilitates the development of a highly accurate temperature measurement method. For the model, its parameters were determined on the calibration stand. The correct operation of the developed method and the effectiveness of temperature measurement have been confirmed by tests on a test stand using reference radiation sources.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11398128PMC
http://dx.doi.org/10.3390/s24175831DOI Listing

Publication Analysis

Top Keywords

body temperature
20
temperature measurement
16
temperature
10
measurement
9
thermometers non-contact
8
thermal imaging
8
imaging camera
8
remote measurement
8
measurement human
8
human body
8

Similar Publications

Objective: To determine the impact of prolonged storage of donor lungs at 10°C of up to 24h on outcome after lung transplantation.

Background: An increasing body of evidence suggests 10°C as the optimal storage temperature for donor lungs. A recent study showed that cold ischemic times can be safely expanded to >12h when lungs are stored at 10°C.

View Article and Find Full Text PDF

Heat acclimation defense against exertional heat stroke by improving the function of preoptic TRPV1 neurons.

Theranostics

January 2025

Department of Critical Care Medicine and Department of Anaesthesiology, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China, 710032.

Record-breaking heatwaves caused by greenhouse effects lead to multiple hyperthermia disorders, the most serious of which is exertional heat stroke (EHS) with the mortality reaching 60 %. Repeat exercise with heat exposure, termed heat acclimation (HA), protects against EHS by fine-tuning feedback control of body temperature (Tb), the mechanism of which is opaque. This study aimed to explore the molecular and neural circuit mechanisms of the HA training against EHS.

View Article and Find Full Text PDF

Wearable sensors with multiple functions are attracting significant attention due to their broad applications in health monitoring and human-computer interaction. Despite significant progress in wearable sensors, it is a significant challenge to monitor temperature and stress simultaneously with a single sensor. A wearable multifunctional optical sensor based on Er/Yb co-doped GdO nanoparticles and a tapered U-shaped fiber is proposed to monitor both temperature and stress in this paper.

View Article and Find Full Text PDF

Background: Infrared thermography technology is a diagnostic imaging modality that converts temperature information on the surface of the human body into visualised thermograms. This technology has the capacity to intuitively detect the presence of certain abnormal conditions or foci in the human body. In recent years, the application of this technology in medicine has become increasingly extensive, especially in the areas of auxiliary diagnosis and early screening of diseases.

View Article and Find Full Text PDF

Background: Neurobrucellosis, a serious central nervous system infection caused by Brucella species, presents significant challenges due to its diverse clinical manifestations and the risk of long-term complications and poor outcomes. Identifying predictors of adverse outcomes is critical for improving patient management and overall prognosis.

Objectives: This study aimed to evaluate the long-term morbidity and mortality associated with neurobrucellosis and to identify key predictors of adverse outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!