Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bone mineral density (BMD) varies with aging and both systemic and local diseases; however, such evidence is lacking in feline medicine. This may be due to the need for general anesthesia in cats for direct BMD measurements using dual-energy X-ray absorptiometry (DXA) or quantitative computed tomography (QCT). In this study, computed digital absorptiometry (CDA), an indirect relative BMD-measuring method, was optimized to select an X-ray tube setting for the quantitative assessment of the feline knee joint. The knee joints of nine cats were radiographically imaged and processed using the CDA method with an aluminum density standard and five X-ray tube settings (from 50 to 80 kV; between 1.2 and 12 mAs). The reference attenuation of the X-ray beam for ten steps (S1-S10) of the density standard was recorded in Hounsfield units (HU), compared between X-ray tube settings, and used to determine the ranges of relative density applied for radiograph decomposition. The relative density decreased ( < 0.0001) with an increase in kV and dispersed with an increase in mAs. Then, the percentage of color pixels (%color pixels), representing ranges of relative density, was compared among S1-S10 and used for the recognition of background artifacts. The %color pixels was the highest for low steps and the lowest for high steps ( < 0.0001), regardless of X-ray tube settings. The X-ray tube setting was considered the most beneficial when it effectively covered the lowest possible HU ranges without inducing background artifacts. In conclusion, for further clinical application of the CDA method for quantitative research on knee joint OA in cats, 60 kV and 1.2 mAs settings are recommended.