A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control Circuits for Potentiostatic/Galvanostatic Polarization and Simultaneous Chemical Sensing by a Light-Addressable Potentiometric Sensor. | LitMetric

A light-addressable potentiometric sensor (LAPS) is a semiconductor-based sensor platform for sensing and imaging of various chemical species. Being a potentiometric sensor, no faradaic current flows through its sensing surface, and no electrochemical reaction takes place in the course of LAPS measurement. In this study, a four-electrode system is proposed, in which a LAPS is combined with the conventional three-electrode electrochemical system. A LAPS is included as the fourth electrode for potentiometric sensing and imaging of the target analyte in the course of an electrochemical reaction taking place on the surface of the working electrode. The integrated system will be useful for analyzing dynamic processes, where both the electrochemical process on the electrode surface and the ion distribution in the solution need to be simultaneously investigated. Different grounding modes of control circuits that can simultaneously conduct potentiostatic/galvanostatic polarization and LAPS measurement are designed, and their functionalities are tested. The interference between polarization and LAPS measurement will also be discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11398221PMC
http://dx.doi.org/10.3390/s24175666DOI Listing

Publication Analysis

Top Keywords

potentiometric sensor
12
laps measurement
12
control circuits
8
potentiostatic/galvanostatic polarization
8
light-addressable potentiometric
8
sensing imaging
8
electrochemical reaction
8
polarization laps
8
laps
6
circuits potentiostatic/galvanostatic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!