Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Despite BIA emerging as a clinical tool for assessing older adults, it remains unclear how to calculate whole-body impedance (Z), reactance (Xc), resistance (R), and phase angle (PhA) from segmental values using modern BIA devices that place electrodes on both sides of the body. This investigation aimed to compare both the whole-body and segmental device-generated phase angle (PhA) with the phase angle calculated using summed Z, Xc, and R from the left, right, and combined sides of the body (PhA) and to compare bioelectric variables between sides of the body. A sample of 103 community-dwelling older adults was assessed using a 50 kHz direct segmental multifrequency BIA device. Whole-body PhA values were assessed for agreement with PhA using 2.5th and 97.5th quantile nonparametric limits of agreement and Spearman's rho. Bioelectrical values between sides of the body were compared using Wilcoxon rank and Spearman's rho. A smaller mean difference was observed between PhA and right PhA (-0.004°, = 0.26) than between PhA on the left (0.107°, = 0.01) and on the combined sides (0.107°, < 0.001). The sum of Z, R, and PhA was significantly different ( < 0.01) between the left (559.66 ± 99.55 Ω, 556.80 ± 99.52 Ω, 5.51 ± 1.5°, respectively) and the right sides (554.60 ± 94.52 Ω, 552.02 ± 94.23 Ω, 5.41 ± 0.8°, respectively). Bilateral BIA values do not appear to be interchangeable when determining whole-body measurements. Present data suggest that using right-sided segmental values would be the most appropriate choice for calculating whole-body bioelectrical variables.