To achieve uniform cooling and effective homogenization control in ultra-large beam-blank molds necessitates the optimization of submerged-entry-nozzle (SEN) structures. This study employed computational fluid dynamic (CFD) modeling to investigate the impact of two-port and three-port SEN configurations on fluid flow characteristics, free-surface velocities, temperature fields, and solidification behaviors. Subsequently, integrating numerical simulations with the non-dominated sorting genetic algorithm II (NSGA-II) and metallurgical quality-control expertise facilitated the multi-objective optimization of a three-port SEN structure suitable for beam-blank molds. The optimized parameters enabled the three-port SEN to deliver molten steel to the meniscus at an appropriate velocity while mitigating harmful effects such as SEN port backflow, excessive surface temperature differences, and shell thickness reduction due to fluid flow. The results indicated that the three-port SEN enhanced the molten-steel flow pattern and mitigated localized shell thinning compared with the two-port SEN. Additionally, the optimized design (op2) of the three-port SEN exhibited reduced boundary layer separation and superior fluid dynamics performance over the initial three-port SEN configuration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11395930PMC
http://dx.doi.org/10.3390/ma17174346DOI Listing

Publication Analysis

Top Keywords

three-port sen
24
sen
9
genetic algorithm
8
ultra-large beam-blank
8
beam-blank molds
8
fluid flow
8
three-port
6
optimization design
4
design submerged-entry-nozzle
4
submerged-entry-nozzle structure
4

Similar Publications

"Three-in-One Wonder": A Retrospective Cohort Study on Modified Robotic-Assisted Transoral Thyroidectomy.

J Otolaryngol Head Neck Surg

December 2024

Department of Thyroid Surgery, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, Changsha, Hunan, P. R. China.

Importance: With advancements in robotic surgery, robotic-assisted thyroidectomy is gaining popularity. The introduction of the 3-port transoral robotic thyroidectomy (T-TORT) offers an alternative approach with potential benefits in postoperative recovery compared to traditional methods.

Objective: To assess the safety and feasibility of T-TORT in comparison to the transoral endoscopic thyroidectomy vestibular approach (TOETVA).

View Article and Find Full Text PDF

To achieve uniform cooling and effective homogenization control in ultra-large beam-blank molds necessitates the optimization of submerged-entry-nozzle (SEN) structures. This study employed computational fluid dynamic (CFD) modeling to investigate the impact of two-port and three-port SEN configurations on fluid flow characteristics, free-surface velocities, temperature fields, and solidification behaviors. Subsequently, integrating numerical simulations with the non-dominated sorting genetic algorithm II (NSGA-II) and metallurgical quality-control expertise facilitated the multi-objective optimization of a three-port SEN structure suitable for beam-blank molds.

View Article and Find Full Text PDF

Reduced-port laparoscopic surgery (RPLS) has been widely used for the radical resection of gastrointestinal tumors. Single-surgeon, three-port, laparoscopic radical resection for sigmoid colon or high rectal cancer with natural orifice specimen extraction surgery (NOSES) has the advantage of a small incision, quick postoperative recovery, and short hospital stay. Yet, there are still only a few reports on NOSES.

View Article and Find Full Text PDF

[Zhu's trocar placement in laparoscopic appendectomy in the treatment of complicated appendicitis].

Zhonghua Wei Chang Wai Ke Za Zhi

August 2018

Department of Laparoscopic Surgery, The First Affiliated Hospital, Wenzhou Medical University, Wenzhou 325000, China.

Objective: To evaluate the feasibility and efficacy of Zhu's trocar placement (ZTP) in laparoscopic appendectomy (LA) in the treatment of complicated appendicitis.

Methods: Clinical data of 139 complicated appendicitis patients undergoing LA at the First Affiliated Hospital of Wenzhou Medical University from June 2013 to December 2017 were retrospectively analyzed. ZTP-LA group comprised 59 cases and its procedure was as follows: 10 mm umbilical trocar was used as lens port; 12 mm trocar at crossing point of umbilical hole horizontal line and right midclavicular line was used as main operating port; 5 mm trocar at the crossing point of horizontal line 0-3 cm below umbilicus and right anterior axillary line was used as assist operating port with the drainage function for Douglas fossa and right iliac fossa; The operator and the assistant stood on the right side and the left side of the patient respectively.

View Article and Find Full Text PDF

Purpose: We previously designed a novel foldable capsular vitreous body (FCVB) to treat severe retinal detachment and evaluated its performance in a 1-year follow up study. The purpose of this study was to determine the efficacy and safety of a silicone oil (SO)-filled FCVB in a 3-year follow-up.

Methods: Standard three-port pars plana vitrectomy was performed, and the FCVB was triple folded and implanted in the vitreous cavity of three eyes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!