A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biocompatibility Evaluation of an Artificial Metallic Bone with Lattice Structure for Reconstruction of Bone Defect. | LitMetric

Biocompatibility Evaluation of an Artificial Metallic Bone with Lattice Structure for Reconstruction of Bone Defect.

Materials (Basel)

Division of Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, 19-1, Uchimaru, Morioka 020-8505, Japan.

Published: August 2024

Mandibular reconstruction for large bone defects is performed with consideration of patients' specific morphology and sufficient strength. Metal additive manufacturing techniques have been used to develop biomaterials for mandibular reconstruction. Titanium artificial mandibles with a lattice structure have been proposed, and the optimal conditions for their strength to withstand mechanical stress around the mandible have been reported. This study investigated the biocompatibility of a titanium artificial bone with a lattice structure fabricated under optimal conditions. The samples were fabricated using metal additive manufacturing. Body diagonals with nodes (BDN) were selected as suitable lattice structures. Dode medium (DM) was selected for comparison. The samples were implanted into rabbit tibial defects and resected with the surrounding bone at two and four weeks. Specimens were evaluated radiographically, histologically, and histomorphometrically. Radiopacity in each lattice structure was observed at two and four weeks. Histological evaluation showed trabecular bone-like tissue inside the BDN compared to the DM at four weeks. No significant differences were noted in the bone volume inside the structures. This study demonstrated the in vivo compatibility of artificial metallic bones with a BDN structure under mechanical stress conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11395923PMC
http://dx.doi.org/10.3390/ma17174286DOI Listing

Publication Analysis

Top Keywords

lattice structure
16
artificial metallic
8
bone lattice
8
mandibular reconstruction
8
metal additive
8
additive manufacturing
8
titanium artificial
8
optimal conditions
8
mechanical stress
8
bone
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!