The long-term effects of implant properties, such as implant length, platform switch, and crown splinting, on peri-implant health require more investigation. Therefore, the aim was to assess the long-term peri-implant health and patient satisfaction in a patient cohort, obtained from two prospective randomized controlled trials, who received 8.5 mm long dental implants, with either splinted or solitary suprastructures and with or without a platform switch, over a period of 15 years. One hundred and twenty-two patients received either one or two 8.5 mm long dental implants (223 dental implants) with and without platform switch, restored with either a solitary ( = 89) or a splinted ( = 134) restoration in the posterior region. Clinical and radiographical parameters and patient satisfaction were prospectively recorded at 1 month, and 1, 5, and 15 years after the placement of the restoration. Patient satisfaction was recorded with a self-administered questionnaire using a 5-point scale and a visual analog scale (0-10). Eighty-one patients with one hundred and fifty-four implants were assessed after a 15-year follow-up. The clinical parameters were low and comparable between the implant types (OsseoTite XP Certain, OsseoTite XP Certain Prevail, NanoTite XP Certain, NanoTite XP Certain Prevail, PalmBeach Gardens, FL, USA) over time. The implants that incorporated a platform switch showed significantly less bone loss than the implants without a platform switch (-0.37 mm, 95% CI -0.69 to -0.05 mm, = 0.024 and β = -0.47, 95% CI -0.80 to -0.14, = 0.006). The implants with splinted restorations experienced more bone loss over time compared to the implants with solitary restorations (0.39 mm, 95% CI 0.15-0.63, = 0.002). Patient satisfaction was high after 15 years. All the tested dental implants with 8.5 mm length provide satisfactory 15-year results with regard to the clinical and radiographical parameters as well as patient satisfaction. The platform-matched implants were associated with more bone loss compared to the platform-switched implants, and the implants with splinted crowns portrayed more bone loss than the solitary implant crowns.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11396484PMC
http://dx.doi.org/10.3390/jcm13175162DOI Listing

Publication Analysis

Top Keywords

dental implants
20
platform switch
20
patient satisfaction
20
bone loss
16
implants
13
long dental
12
implants splinted
12
splinted solitary
8
solitary implant
8
peri-implant health
8

Similar Publications

Background: Dental implantation of bone reconstructions in oncologic situations improves patients' orofacial function and quality of life. There are currently no recommendations on the timing of implantation.

Methods: This systematic review with meta-analysis aimed to compare primary and secondary dental implantation of free bone flaps in reconstructions for malignant tumors of the oral cavity.

View Article and Find Full Text PDF

Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.

Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.

View Article and Find Full Text PDF

Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.

Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.

View Article and Find Full Text PDF

Digital planning and decision making for severe congenital oligodontia with Angle class-III malocclusion - Case series.

J Craniomaxillofac Surg

December 2024

Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel; Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; Department of Oral and Maxillofacial rehabilitation, Rambam Health Care Campus, Haifa, Israel.

As maxillofacial surgery becomes increasingly digitized and the transformative impact of pre-surgical scanning and computer simulation is recognized, this clinical paper presents an algorithm for the selection of interventions in severe congenital oligodontia with Angle class-III malocclusion (OCIII) utilizing such technologies. A complex, multifactorial condition with varying degrees of craniofacial involvement, OCIII is associated with edentulous facial appearance, mandibular prognathism and deep underbite, as well as malocclusion. Our methodology involves the integration of CBCT imaging, intra- and extra- oral scanning, and 3D planning with the assessment of bone volume, number of missing teeth, skeletal discrepancies, and patient compliance in the selection of suitable treatments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!