A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-Dimensionally Printed Elastic Cardiovascular Phantoms for Carotid Angioplasty Training and Personalized Healthcare. | LitMetric

Atherosclerosis is becoming increasingly common in modern society. Owing to the increasing number of complex angioplasty procedures, there is an increasing need for training in cases where the risk of periprocedural complications is high. A procedure was developed to obtain three-dimensional (3D) models and printing of blood vessels. The mechanical and optical properties of the printed materials were also examined. Angioplasty and stent implantation were tested, and the phantom was compared with the clinical data of patients who underwent interventional treatment. Both laser techniques and cone-beam computed tomography of the phantoms were used for comparison. The printed material exhibited mechanical parameters similar to those of blood vessel walls. The refractive index of 1.473 ± 0.002 and high transparency allowed for non-invasive laser examination of the interior of the print. The printed models behaved similarly to human arteries in vivo, allowing training in treatment procedures and considering vessel deformation during the procedure. Models with stents can be analyzed using laser and cone-beam computed tomography to compare stents from different manufacturers. The developed methodology allows for simple and time-efficient production of personalized vessel phantoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11396471PMC
http://dx.doi.org/10.3390/jcm13175115DOI Listing

Publication Analysis

Top Keywords

cone-beam computed
8
computed tomography
8
three-dimensionally printed
4
printed elastic
4
elastic cardiovascular
4
cardiovascular phantoms
4
phantoms carotid
4
carotid angioplasty
4
angioplasty training
4
training personalized
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!