Near-Infrared On-Site Evaluation (NOSE) Examination of EBUS/EUSb Samples-A New Method for Sample Adequacy Evaluation.

Diagnostics (Basel)

1st Clinic of Tuberculosis and Respiratory Diseases, General University Hospital in Prague, U Nemocnice 2, Prague 2, 120 00 Prague, Czech Republic.

Published: August 2024

Fine-needle aspiration biopsy is crucial for modern diagnostics of endoscopic procedures and thus an efficient and reliable method for increasing biopsy yields is urgently needed. In our study, we address the limited availability and high price of the rapid onsite evaluation (ROSE) technique by introducing the technique of near-infrared on-site evaluation (NOSE) consisting of spectral measurement of near-infrared radiation (NIR) transmitted through the evaluated material. For this purpose, we designed a special optical probe consisting of two fibres, of which one is a source fibre and the second is a detector fibre. The distal ends of both fibres are brought together into one bundle which is, with the help of a special extension, applied to a cuvette with an analysed sample at a defined distance from the cuvette bottom and fixed in place. A portion of the NIR radiation received by the detector fibre after it propagates through the sample then depends on the optical and therefore morphological characteristics of the sample. Based on the measured spectral curve, we can calculate the attenuation coefficient curve and subsequently the parameter of the sample richness and the parameter characterising the autofluorescence peak as well. We found that the value of our introduced parameters is in significant relation to sample richness as well as to sample malignity. NOSE evaluation of EBUS/EUSb (endobronchial/oesophageal ultrasound bronchoscopy) specimens can be considered an easy new technique aiming to improve sampling diagnostic accuracy and to diminish costs related to the presence of a cytopathologist and related instrumentation in the endoscopy suite.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11394049PMC
http://dx.doi.org/10.3390/diagnostics14171887DOI Listing

Publication Analysis

Top Keywords

near-infrared on-site
8
on-site evaluation
8
evaluation nose
8
detector fibre
8
sample richness
8
sample
7
evaluation
5
nose examination
4
examination ebus/eusb
4
ebus/eusb samples-a
4

Similar Publications

Miniaturized spectrometers have significantly advanced real-time analytical capabilities in fields such as environmental monitoring, healthcare diagnostics, and industrial quality control by enabling precise on-site spectral analysis. However, achieving high sensitivity and spectral resolution within compact devices remains a significant challenge, particularly when detecting low-concentration analytes or subtle spectral variations critical for chemical and molecular analysis. This study introduces an innovative approach employing guided-mode resonance filters (GMRFs) to address these limitations.

View Article and Find Full Text PDF

The application and development of fast and simple screening methods for the authentication of foods has increased continuously in recent years. A widely used analytical technique is Fourier transform near-infrared spectroscopy (FT-NIR). Despite the simple application of FT-NIR analysis, the analyses are usually carried out on benchtop devices in the laboratory.

View Article and Find Full Text PDF

Near-infrared (NIR) spectroscopy has gained wide acceptance across various fields as a result of advances in portable equipment that can record spectra on site or at production lines. Continuous wavelet transform (CWT) can transform traditional one-dimensional (1D) NIR spectra into more informative two-dimensional (2D) spectrograms, thus enhancing the analysis and interpretation of spectral information. This study introduces a high-efficiency 2D CWT-EfficientNetV2 regression model to optimize NIR spectroscopy applications.

View Article and Find Full Text PDF

Achieving high production in the top coal caving process from thick coal seams is crucial. Thus, the timely decision of when to stop caving poses an urgent challenge to impact the mining loss rate and cost recovery. To address this issue, an innovative recognition system has been developed using Near-Infrared Spectroscopy (NIRS) technology.

View Article and Find Full Text PDF

Cr-activated garnet phosphors with broadband near-infrared (NIR) emission have attracted considerable interest due to their high quantum efficiency (QE) and thermal stability for widespread advanced applications. Nevertheless, how to achieve energy-saving broadband NIR phosphors that possess anti-thermal quenching (anti-TQ) without compromising the high QE has yet to be fully addressed. Herein, we report on site reconstruction within the garnet lattice by strategically positioning Sc and Ga atoms into octahedral B sites with a mole ratio of 1 : 1 to produce GdScGaO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!