This study investigated the impact of drying parameters on the quality of fingerroot () extract, focusing on phenolic compounds, flavonoids, and antioxidant activity. A Box-Behngen design was employed to evaluate the effects of maltodextrin concentration, inlet temperature, and outlet temperature on the extract's properties. The highest total phenolic content (18.96 µg of GAE/mg extract) and total flavonoid content (33.52 µg of GE/mg extract) were achieved using 20% maltodextrin, a 160 °C inlet temperature, and an 80 °C outlet temperature. Antioxidant activity, measured by DPPH and FRAP assays, was also influenced by drying parameters. Stepwise regression analysis revealed that maltodextrin concentration significantly affected all responses, while the inlet temperature had no significant effect. The outlet temperature significantly influenced FRAP activity. The developed mathematical models accurately predicted experimental values, validating the effectiveness of the RSM and Deep-Learning Machine. Optimal drying conditions for maximizing phenolic compounds were determined to be 20% maltodextrin, a 150 °C inlet temperature, and a 70 °C outlet temperature, resulting in TPC 15.33 µg of GAE/mg extract, TF 28.75 µg of GE/mg extract, IC value of 3.99 µg/mL, FRAP value at 4.44 µmoL Fe/mg extract of phenolic content, and 18.96 µg of the GAE/mg extract. Similar conditions were found to be optimal for maximizing flavonoid content. These findings provide valuable insights for optimizing the drying process of fingerroot extract to preserve its bioactive compounds and enhance its potential applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11395052PMC
http://dx.doi.org/10.3390/foods13172676DOI Listing

Publication Analysis

Top Keywords

inlet temperature
16
outlet temperature
16
antioxidant activity
12
µg gae/mg
12
gae/mg extract
12
drying parameters
8
extract
8
fingerroot extract
8
phenolic compounds
8
maltodextrin concentration
8

Similar Publications

This article introduces an innovative multipurpose system that integrates a solar power plant with a coastal wind farm to generate refrigeration for refinery processes and industrial air conditioning. The system comprises multiple wind turbines, solar power plants, the Kalina cycle to provide partial energy for the absorption refrigeration cycle used in industrial air conditioning, and a compression refrigeration cycle for propane gas liquefaction. An extensive energy and exergy analysis was conducted on the proposed system, considering various thermodynamic parameters such as the solar power plant's energy output, the absorption chiller's cooling load, the electricity generated by the turbines, the wind turbines' power output, and the energy efficiency and exergy of each cycle within the system.

View Article and Find Full Text PDF

In response to the ongoing quest for more efficient renewable energy sources, this research addresses a significant gap in understanding the performance variations of Solar Chimney Power Plant (SCPP) models, particularly focusing on the influence of flow parameters in full and half-inclined collector sections featuring semi-elliptical curvature. The motivation stems from the need to optimize SCPP designs for enhanced energy generation while minimizing resource utilization and environmental impact. This research focuses on investigating flow parameter variations in Solar Chimney Power Plant (SCPP) models with full and half-inclined collector sections featuring semi-elliptical curvature and variable semi-minor heights (b: 0.

View Article and Find Full Text PDF

Predicting the abundance of Lepeophtheirus salmonis in the Bay of Fundy, New Brunswick.

J Aquat Anim Health

December 2024

Department of Health Management and Centre for Veterinary Epidemiological Research, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.

Objective: The primary objective was to construct a time series model for the abundance of the adult female (AF) sea lice Lepeophtheirus salmonis in Atlantic Salmon Salmo salar farms in the Bay of Fundy, New Brunswick, Canada, for the period 2016-2021 and to illustrate its short-term predictive capabilities.

Methods: Sea lice are routinely counted for monitoring purposes, and these data are recorded in the Fish-iTrends database. A multivariable autoregressive linear mixed-effects model (second-order autoregressive structure) was generated with the outcome of the abundance of AF sea lice and included treatments, infestation pressures (a measure that represents the dose of exposure of sea louse parasitic stages to potential fish hosts) within sites (internal) and among sites (external), and other predictors.

View Article and Find Full Text PDF

Numerical investigation of performance and exergy analysis in parabolic trough solar collectors.

Sci Rep

December 2024

Department of Mechanical and Aerospace Engineering, School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand, 248007, India.

This numerical investigation examines the performance and exergy analysis of parabolic trough solar collectors, focusing on the substitution of the conventional circular absorber with a rhombus-shaped absorber. By evaluating the thermal and fluid dynamics properties, this study aims to identify improvements in overall system performance and efficiency. This numerical study conducts a comprehensive thermal analysis of parabolic trough solar collectors by comparing a rhombus-shaped absorber with a conventional circular absorber.

View Article and Find Full Text PDF

Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!