Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The purpose of this study was to evaluate the performance of four-dimensional (4D) flow cardiac MRI in quantifying aortic flow in patients with bicuspid aortic valve (BAV).
Materials And Methods: Patients with BAV who underwent transthoracic echocardiography (TTE) and 4D flow cardiac MRI were prospectively included. Aortic flow was quantified using two-dimensional phase contrast velocimetry at the sinotubular junction and in the ascending aorta and using 4D flow in the regurgitant jet, in the left ventricular outflow tract, at the aortic annulus, the sinotubular junction, and the ascending aorta, with or without anatomical tracking. Flow quantification was compared with ventricular volumes, pulmonary flow using Pearson correlation test, bias and limits of agreement (LOA) using Bland Altman method, and with multiparametric transthoracic echocardiography quantification using weighted kappa test.
Results: Eighty-eight patients (63 men, 25 women) with a mean age of 50.5 ± 14.8 (standard deviation) years (age range: 20.8-78.3) were included. Changes in flow with or without tracking were modest (< 5 mL). The best correlation was obtained at the aortic annulus for forward volume (r = 0.84; LOA [-28.4; 25.3] mL) and at the regurgitant jet and sinotubular junction for regurgitant volume (r = 0.68; LOA [-27.8; 33.8] and r = 0.69; LOA [-28.6; 24.2] mL). A combined approach for regurgitant fraction and net volume calculations using forward volume measured at ANN and regurgitant volume at sinotubular junction performed better than each level taken separately (r = 0.90; LOA [-20.7; 10.0] mL and r = 0.48, LOA [-33.8; 33.4] %). The agreement between transthoracic echocardiography and 4D flow cardiac MRI for aortic regurgitation grading was poor (kappa, 0.13 to 0.42).
Conclusion: In patients with BAV, aortic flow quantification by 4D flow cardiac MRI is the most accurate at the annulus for the forward volume, and at the sinotubular junction or directly in the jet for the regurgitant volume.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.diii.2024.09.001 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!